Pelsis CURTIS DYNA-FOG HURRICANE ES HESEU User Manual Download Page 5

strongly recommended that all such sources be eliminated in the appropriate manner. To avoid danger of fire or explosion in 

an enclosed space, the enclosed volume fogging time and required formulation volume should be carefully calculated. While 

operating the machine, always carry the machine by the carrying handle to ensure that you are properly grounded.

5.  Proper and Improper Use

.

The following rules apply to the operation of this machine:

DO read the entire manual before operating the machine and pay particular attention to all

CAUTIONS AND WARNINGS

 •

  Only use water-base formulations with this machine

 •

  Store formulation in its original labelled container.

 •

  Only use a 3-prong grounded extension lead which is properly rated for voltage, current, and length and which is 

free from nicks, cracks, and other signs of prior abuse. For lengths up to 30.5 metres. Leads with No. 12 AWG wire are 

adequate.

 •

  Turn off the appliance before unplugging. Unplug by grasping the plug. Do not pull on the lead to unplug. Do not unplug 

machine with wet hands.

 •

  Replace damaged or worn electric lead immediately.

 •

  Turn the flow valve CLOCKWISE to the OFF position after each fogging application while the motor is still operating to 

allow clearing of the lines. 

 •

  Always comply with any requirements for protective clothing, goggles, facial masks, or respiratory equipment required 

by the formulation label.

 

  Ensure that formulation is applied only in strict compliance with the formulation label. 

DO NOT

 •

 Do not use oil-based or flammable formulations with this machine.

 •

 Do not use a machine that is broken or damaged in any way.

 •

 Do not alter the machine by adding or removing parts.

 •

 Do not restrict the motor blower air intake area.

 •

 Do not tamper with the output nozzle or 3-prong electrode and charging ring (collector).

 •

 Do not allow the machine to operate unattended.

 •

 Do not stand in water or hold over water while operating machine.

 •

 Do not allow the power lead or extension lead to be submersed in water.

 •

 Do not use outdoors when it’s raining.

 •

  Do not apply more than 2.7 litres per 1,000 cubic metres in an enclosed space. Exceeding this concentration is both 

hazardous and wasteful.

 •

 Do not touch the 3-prong electrode while the machine is operating.

 

Summary of Contents for CURTIS DYNA-FOG HURRICANE ES HESEU

Page 1: ...230V electrostatic fogger USER MANUAL ...

Page 2: ...e product THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE EXCLUDED AND CURTIS DYNA FOG SHALL HAVE NO LIABILITY FOR ANY CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES EVEN IF CURTIS DYNA FOG WAS APPRISED OF THE POSSIBILITY THEREOF In no event shall CURTIS DYNA FOG s liability hereunder exceed the amount of the purchase price paid for the product Any warranty claim must...

Page 3: ... FIRE EXPLOSION OR ELECTRICAL SHOCK HAZARD MODEL HESUK 10001 SERIAL UNITED STATES PATENT 4 177 949 CANADIAN PATENT 1 101 381 230V 50Hz 4 15A POWER 930W DISCONNECT THE POWER SUPPLY BEFORE SERVICING Pelsis Ltd HG5 8PJ UK Pelsis Belgium NV Bornem 2880 WARNING Read and understand operator s manual and all other safety instructions before using this equipment WARNING Always have the machine serviced by...

Page 4: ...e of this appliance This appliance is designed to operate from three wire power systems where one of the wires is a safety ground Use a GFCI Ground Fault Circuit Interrupter power outlet whenever possible Do not disconnect the safety ground or use extension leads or cheater plugs to connect this machine to a two wire system This machine must be used with a 3 prong grounded extension lead plugged i...

Page 5: ...t unplug machine with wet hands Replace damaged or worn electric lead immediately Turn the flow valve CLOCKWISE to the OFF position after each fogging application while the motor is still operating to allow clearing of the lines Always comply with any requirements for protective clothing goggles facial masks or respiratory equipment required by the formulation label Ensure that formulation is appl...

Page 6: ...output and particle size are dependent upon the viscosity of the liquid being dispensed See table 2 for particle size vs valve setting flow rate Hurricane ES HESUK Hurricane ES HESEU Motorized Blower High efficiency Motor Blower Brush Life Approximately 1000 hours Electrostatic Power Supply 230V Current Draw 230V 3 40 A 50Hz Nozzle Type Professional grade electrostatic 3 nozzle air assist vortical...

Page 7: ...it clockwise There are three flow indicator marks on the side of the tank that designate position 1 position 2 and position 3 All flow rate information is based on using water with a temperature of 21 C Increasing the viscosity will decrease flow rate and can increase droplet size Refer to the table below for approximate flow rates and droplet sizes at the various valve settings Droplet sizes are ...

Page 8: ...ver smaller size droplets in the 10 20 micron range can be effective when targeting microorganisms suspended in the air Formulation Tube Metering Valve Approximate flow rates for the valve position settings are as follows Position Flow rate Droplet Size Microns 1 60 ml min 10 20 2 90 ml min 20 30 3 120ml min 30 50 Flow rates shown are approximate and will vary depending on liquid viscosity and tem...

Page 9: ...the electrical lead for evidence of damage and replace any damaged lead immediately 3 Clean the Air Intake Filter after every application If the filter gets saturated wet and dripping while the machine is working stop the machine and clean the filter 7 0 Noise Level The Hurricane ES noise levels do not require hearing protection however we would still recommend it especially when using it for prol...