This machine contains an electrostatic device that may interfere with sensitive medical devices such as pacemakers and
defibrillators, etc. DO NOT operate this machine or stand within 3 metres if you use any such medical devices. Contact your
physician prior to operation if you are unsure if this machine will interfere with your medical device.
This machine contains an electrostatic device that may cause an electrical shock if not properly grounded. Always use a
three (3) prong grounded extension lead at the ratings shown in the table when using an extension lead.
Hold the appliance when operating so that your hand remains in contact with the grounding strip located underneath the
carrying handle. Leaving the appliance unattended while in operation can cause a build-up of electrostatic charge that can
cause a static shock. Note: Objects in the vicinity of the machine may develop an electrostatic charge during operation.
WARNING
Please read and understand these safety precautions before operating this appliance. Failure to properly follow
these precautions may lead to a serious incident, such as a fire, explosion, or electrical shock hazard.
1. Electric Power.
Precautions:
This machine uses electrical power at common commercially available voltages. When directly contacted, such voltages
are hazardous to human life. All precautions commonly applicable to the use of the electric power are generally applicable
to the use of this appliance. This appliance is designed to operate from three wire power systems where one of the wires is
a safety ground. Use a GFCI (Ground Fault Circuit Interrupter) power outlet whenever possible. Do not disconnect the safety
ground or use extension leads or “cheater” plugs to connect this machine to a two-wire system. This machine must be used
with a 3-prong grounded extension lead plugged into a grounded electrical supply.
Extension Leads:
Extension leads must be properly sized and rated for the voltage, current, and length of an individual lead. Consult the
nameplate current and voltage rating of your machine and the marked rating of the extension lead. A single extension lead
only should be used. When two or more extension leads are placed in a series, the rated current carrying capacities of the
leads may no longer be valid. If an extension lead becomes warm to touch, discontinue its use and obtain a lead with a
higher current rating. Improper extension leads are not only hazardous, but may result in poor machine performance due to
excessive voltage drop.
2. Formulations.
This machine is designed for water formulations only. Do not use flammable formulations with this machine and do not spray
it near sources of admission. Oil based formulations must not be used.
3. Aerosol Concentration.
An acceptable level of liquid in the atmosphere is 2.7 litres per 1,000 cubic metres. There is a safety margin of at least 5 to 1
in this figure.
4. Aerosol Ignition.
If a combustible atmosphere is established or a combustible deposit is laid down, a source of ignition may cause a fire. It is