Model: PP 130-B
Hearth & Home Technologies
352 Mountain House Road
Halifax, PA 17032
Table 1.3
–
Test Facility Conditions
Initial
Final
Room Temperature
(°F)
71
69
Barometric Pressure
(in Hg)
30.40
30.44
Air Velocity
(ft/min)
< 50
< 50
Induced Draft
(in H2O)
0.0
0.0
Table 1.4
–
Fuel Measurement Summary
Segment
Time
(min)
Burn Rate
(dry kg/hr)
Consumed
Fuel Weight
(lbs)
Fuel Moisture
Content
(dry basis - %)
Pretest
60
2.48
5.8
5.91
Maximum
60
2.53
5.9
5.91
Medium
120
1.03
4.8
5.91
Minimum
180
0.60
4.2
5.91
Integrated Total
360
1.06
14.9
5.91