OMNI-Test Laboratories, Inc.
V
m(std)
– Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf
ASTM E2515 equation (6)
Where:
K
1
=
17.64
°
R/in. Hg
V
m
=
Volume of gas sample measured at the dry gas meter, dcf
Y
=
Dry gas meter calibration factor, dimensionless
P
bar
=
Barometric pressure at the testing site, in. Hg
∆
H
=
Average pressure differential across the orifice meter, in. H
2
O
T
m
=
Absolute average dry gas meter temperature,
°
R
Sample Calculation:
Using equation for Train 1:
1.33
V
m(std)
= 17.64
x 59.062 x
0.977
x
13.6
(
82.2
+
460
)
V
m(std)
=
57.456
dscf
Using equation for Train 2:
1.04
V
m(std)
= 17.64
x 57.071 x
0.979
x
13.6
(
82.5
+
460
)
V
m(std)
=
55.560
dscf
Using equation for ambient train:
0.00
V
m(std)
= 17.64
x 55.10 x
0.997
x
13.6
(
73.3 +
460
)
V
m(std)
=
55.430
dscf
)
+
30.51 +
)
( 30.51
30.51 +
(
(
)
m
bar
m
std
m
T
H
P
Y
V
K
V
6
.
13
1
)
(
Control No. P-SFDK-0002, Effective date: 5/06/2016
File - 135PS040E PP70 Run 1, Tab - Example Calculations
64 of 112
Summary of Contents for PP130-B
Page 15: ...1445 North Hwy Colville WA 99114 800 234 2508 Low 15 of 112 ...
Page 28: ...28 of 112 ...
Page 29: ...29 of 112 ...
Page 33: ...33 of 112 ...
Page 35: ...35 of 112 ...
Page 36: ...36 of 112 ...
Page 37: ...37 of 112 ...
Page 38: ...38 of 112 ...
Page 39: ...39 of 112 ...
Page 41: ...41 of 112 ...
Page 42: ...42 of 112 ...
Page 43: ...43 of 112 ...
Page 44: ...44 of 112 ...
Page 47: ...1 19 2018 47 of 112 ...
Page 50: ...1 19 2018 50 of 112 ...
Page 51: ...51 of 112 ...
Page 52: ...52 of 112 ...
Page 53: ...53 of 112 ...
Page 55: ...55 of 112 ...