Can
adian Comfort Industries V04
33
PELPRO OWNERS MANUAL
Copyright 2004
www.pelprostoves.com
Dansons Group Inc.
P
ERIODIC
M
AINTENANCE
SOOT - FLY ASH:
T
he by products of combustion contain small particles of fly ash. Fly ash will collect in the exhaust venting system
and restrict the flow of flue gases. Incomplete combustion, (such as during startup) shutdown or incorrect operation
of the room heater will lead to some sort of soot formation which will collect in the exhaust system. Because of this
it is important that the exhaust system be
inspected and cleaned at least once a year to determine if cleaning
is needed. It is a good practice to inspect after every 1–2 tons of pellet fuel burning.
With proper cleaning and the use of quality pellets, your
PELPRO appliance
requires very little maintenance.
However,
the following periodic maintenance is strongly recommended
. This should be preformed
seasonally, bi-seasonally, or every 1-2 tons of fuel usage.
WARNING:
Unplug your stove's electrical cord prior to opening the sides of the stove or opening the exhaust
system for any inspection, cleaning, maintenance or service work.
NEVER
perform any inspections, cleaning, maintenance or service on a HOT STOVE.
ASH TRAPS:
[COLD STOVE ONLY]
Remove the back plate from the firebox area. This will expose the
two ash traps and the fuel drop shute. Fly ash may be removed by vacuuming inside the trap areas. It is also
good to use a brush (bottle cleaner) to reach up and down to scrape the build up off the metal areas.
BURN GRATE:
Periodically remove
and clean your grate. In particular it is advisable to clean out the
holes to remove any build up that may prevent air from moving through grate freely. If grate has become
plugged with hard residue from burning lower quality fuel, you may need to use a sharp awl or drill bit to
open holes back to their original size.
BURN POT:
This is the “pot” where the pellets are burned in the grate. When removing your grate for
cleaning, check the burn pot area for ash build up. Some ash will fall through the grate holes and build up
under the grate. This needs to be cleaned out to prevent lack of air flow through the burn grate.
DOOR GASKET:
Inspect the main door gasket periodically. The main door may be removed to
have frayed, broken or compacted gaskets replaced by your Authorized
PELPRO
Dealer.
FAN MOTORS:
C
lean the in-take on CONVECTION (ROOM AIR) fan as well as the air holes on
the motors of both COMBUSTION and CONVECTION fans annually. Disassemble the COMBUSTION
AIR FAN and clean out the internal fan blades as part of your fall start up.
FRESH AIR INTAKE
:
Inspect periodically to be sure that it is not clogged with any foreign materials. A
plugged screen will restrict or shut off combustion air and cause a fire to die or burn poorly.
GOLD / BRASS TRIM CLEANING:
Use a damp cloth to clean your gold door.
DO NOT USE
ANY ABRASIVE CLEANERS AS YOU WILL REMOVE OR SCRATCH THE PLATING!
CHECK AND CLEAN THE HOPPER
:
Check the hopper periodically to determine if there is any sawdust or pellets that are sticking to
the hopper surface. Clean as needed.
RIODIC
GLASS (High Temp, Neo-Ceram):
We recommend using a high quality glass cleaner. Should a
build up of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean glass.
Ceramic is very hard and will not scratch from the steel wool.
GLASS REPLACEMENT:
In the event you need replacement only Neo-Ceram of the correct size and
thickness may be used. Contact your local
PELPRO
dealer to obtain this glass.
DO NOT OPERATE STOVE WITH BROKEN GLASS AS LEAKAGE OF FLUE GASES MAY RESULT.