24
12.6
ELECTRIC SCHEME
Pic. 21
Controller wiring diagram,
where:
T1
– CT4 boiler temperature sensor,
OS
– optical flame sensor,
T2
– feeder temperature sensor CT4,
PS
- vacuum sensor,
H
– voltage output to signaling alarms or
signaling controller operation mode or control the reserve boiler or control the circulation pump,
T3
- CT4
hot water temperature sensor,
T4
– CT4-P weather temperature sensor,
T5
– CT2S fumes temperature
sensor,
T6
– CT4 mixer temperature sensor,
RT
– boiler room thermostat input,
HS
– fan revolution sensor,
P
– control panel,
Room Control TOUCH
– room panel with a room thermostat feature (replaces RT),
D-
D+
- connector for additional modules,
B
– module adds the control of another two mixers and a heat
buffer,
C
– module adding the control of another two mixers and circulating pump,
λ
– Lambda probe
module.
L N PE
- 230V AC mains power supply,
FU
– mains fuse,
STB
– safety temperature limiter input,
FO
–
burner blower,
FG
– main feeder,
FH
– burner feeder or rotary grate cleaning mechanism,
FV
– boiler
exhaust fan,
I
– igniter,
PB
– boiler or buffer pump,
PHD
– hot water pump,
PM
– mixer pump,
SM
– mixer
cylinder,
CPU
– control.
Room Control
TOUCH
Summary of Contents for S.Control
Page 1: ......
Page 2: ......
Page 6: ......
Page 7: ...USER MANUAL OF THE CONTROLLER S Control ...
Page 17: ...17 USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS S Control ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ......