F. 

Insert the window from the exterior of the building.

 Place the bottom of 

the window on the spacers at the bottom of the opening, then tilt the top into 
position. Center the window between the sides of the opening to allow clearance 
for shimming. 

 

Windows with nail fin:

 Insert one roofing nail in the first hole from the corner on 

each end of the top nailing fin. These are used to hold the window in place while 
shimming it plumb and square.

 

Windows using screws through the frame:

 Position the window so the exterior 

face of the frame extends 3/4" on the exterior wall material to allow for the 
application of backer rod and sealant (See illustrations in Step 7 for sealant 
details). Center window between the sides of the opening to allow clearance for 
shimming and insert one #10 x 3-1/2" screw into each of the top clearance holes. 
This will hold the window in place while shimming it plumb and square. 

 

Window with Installation Clips:

 Position the window so the exterior face of 

the frame extends 3/4" on the exterior wall material to allow for the application 
of backer rod and sealant (See illustrations in Step 7 for sealant details). Center 
window between the sides of the opening to allow clearance for shimming and 
insert one #6 x 1-1/2" or longer screw into one hole in each of the top corner 
clips. This will hold the window in place while shimming it plumb and square.  
Note: For masonry openings use 3/16" x 1-1/2" masonry screw.

2

SETTING AND FASTENING THE WINDOW  
(CONTINUED)

TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS.

Ř

WINDOWS 

Ř

 ALL

 WINDOWS 

Ř

 ALL

 WINDOWS 

Ř

 ALL

 WINDOWS 

Ř

 ALL

 WINDOWS 

Ř

ALL

 

G.  

Plumb and square the window.

 Place 

shims 1" from the bottom and top of the 
window between the window and the sides 
of the opening. Keep shims back 1/2" 
from the interior face of the window.  
Adjust the shims as required to 
plumb and square the window in 
the opening. If the frame height 
exceeds 53", place shims at the 
midpoint of the window sides. 

Note: DO NOT shim above the 
window or in the space between the 
spacers at the bottom of the window. DO NOT over shim.

H. 

Check the interior reveal. 

Make sure the measurement from the interior 

face of the window to the interior face of the wall is equal at several points 
around the window.

Note: If the dimensions are not equal, check to make sure the fins are 
folded out to 90˚ at all points.

2E

2E

2F

2F

1

2 0 3 0

4 0 5 0

6 0 7 0

2

3

INCHES

mm

2G

2H

Summary of Contents for 801U0103

Page 1: ...aintenance instructions may void your Pella product warranty See Limited Warranty for complete details at http warranty pella com INSTALLATION INSTRUCTION STANDARD PERFORMANCE UPGRADE AND HURRICANESHI...

Page 2: ...framing members REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT A Make sure the bottom of the opening is level Note It is critical the bottom is level for the window to be installed correctl...

Page 3: ...s If installation ns are used place the clip so that the lip is facing up and against the installation n at the locations shown in the placement diagram If installation ns are not used the clip lip fa...

Page 4: ...or sealant details Center window between the sides of the opening to allow clearance for shimming and insert one 6 x 1 1 2 or longer screw into one hole in each of the top corner clips This will hold...

Page 5: ...window Press the tape down rmly while folding down the excess tape at the top and bottom of the window Note DO NOT tape or seal the bottom nailing n C Apply top ashing tape Cut a piece of ashing tape...

Page 6: ...to circle top windows Several pieces of ashing tape will be needed to cover the top n Start taping from the sides of the window working toward the peak To determine the length of cuts hold the tape a...

Page 7: ...ctly follow the foam manufacturer s recommendations for application Use of high pressure foams or improper application of the foam may cause the window frame to bow and hinder operation 6 INTERIOR SEA...

Page 8: ...nstructions for these and any other applications 7 45 4 MFBSBODF BDLFS 3PE BOE 4FBMBOU UZQJDBM OTVMBUJOH PBN 1FSJNFUFS 4FBMBOU NVTU FYUFOE UP SPPNTJEF PG DDFTTPSZ SPPWF DDFTTPSZ SPPWF 800 4 8 5 53 OTV...

Page 9: ...eel wool BE CAREFUL NOT TO SCRATCH THE GLASS Remove sanding dust Note To maintain proper product performance do not paint nish or remove the weather stripping mohair dust pads gaskets or vinyl parts A...

Page 10: ...per management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of allow f...

Reviews: