Installation Instructions for Typical Wood Frame Construction.

These instructions were developed and tested for use with typical wood frame wall construction 
in a wall system designed to manage water. These instructions are not to be used with any 
other construction method. Installation instructions for use with other construction methods, 
multiple units or bow and bay windows, may be obtained from Pella Corporation, a local Pella 
retailer, or by visiting 

http://www.pella.com

. Building designs, construction methods, building 

materials, and site conditions unique to your project may require an installation method 
different from these instructions and additional care. Determining the appropriate installation 
method is the responsibility of you, your architect, or construction professional. 

Part Number: 801U0102

©2008 Pella Corporation 

Always read the Pella

®

 Limited Warranty before purchasing or installing Pella 

products. By installing this product, you are acknowledging that this Limited 

Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance 
instructions may void your Pella product warranty. See Limited Warranty for complete details at 

http://warranty.pella.com.

INSTALLATION INSTRUCTION – INSTRUCCIONES DE INSTALACION 
FOR CLAD FIXED FRAME AND CIRCLEHEAD WINDOWS

8JOEPX#PUUPN

8JOEPX5PQ

/BJMJOH'JO

'JO$PSOFS

8BUFS3FTJTUJWF#BSSJFS

4IFBUIJOH

'SBNJOH

5PQ
'MBTIJOH
5BQF

0VUFS$PSOFS
'MBTIJOH5BQF

0VUFS
7FSUJDBM
'MBTIJOH
5BQF

4JEF
'MBTIJOH
5BQF

4JEF
'MBTIJOH
5BQF

4JMM'MBTIJOH5BQF

4JMM'MBTIJOH5BQF

0VUFS
7FSUJDBM
'MBTIJOH
5BQF

YOU WILL NEED TO SUPPLY:

TOOLS REQUIRED:

s#EDAROR)MPERVIOUSSHIMSSPACERSTO 
sGALVANIZEDROOlNGNAILSLB 
s#LOSEDCELLFOAMBACKERRODSEALANTBACKERTOFT 
s0ELLA

®

 SmartFlash

 foil backed butyl window and 

  door flashing tape or equivalent

s(IGHQUALITYEXTERIORGRADEPOLYURETHANEOR
 SILICONESEALANTTUBEPERWINDOW 
s'REAT3TUFF

 Window and Door Insulating Foam Sealant 

by the Dow Chemical Company or equivalent low pressure 
polyurethane window and door foam - DO NOT use high 

PRESSUREORLATEXFOAMS

s)NTERIORTRIMANDORJAMBEXTENSIONSTOFT 

s4APEMEASURE

s,EVEL

s3QUARE

s(AMMER

s3TAPLER

s3CISSORSORUTILITYKNIFE

s3EALANTGUN

4&"-"/5

4&"-"/5

Summary of Contents for 801U0102

Page 1: ...of the terms of the sale Failure to comply with all Pella installation and maintenance instructions may void your Pella product warranty See Limited Warranty for complete details at http warranty pel...

Page 2: ...ny problems with the rough opening before proceeding C Cut the water resistive barrier 1C Additional cutting patterns given below D Fold the water resistive barrier 1D Fold side aps into the opening a...

Page 3: ...them and store them in a protected area 2 SETTING AND FASTENING THE WINDOW C Fold out installation n to 90 N UNITS WITH PRE APPLIED lN CORNERS BE CAREFUL NOT TO REMOVE OR TEAR THE lN CORNERS Note If t...

Page 4: ...ns are folded out to 90 at all points Fasten the window to opening N WINDOWS WITH A lXED EXTRUDED lN DRILL DIAMETER HOLES IN THE lN EVERY A Units that do not have pre applied n corners UT FOUR PIECES...

Page 5: ...e the length of cuts hold the tape along the radius and cut the tape just past where it LEAVES THE TOP lXED EXTRUDED lN OR FOR THE mEXIBLE lN JUST PAST THE mEXIBLE WEATHER STRIP 4HE top tape must over...

Page 6: ...ll the space from the back of the n to the interior face of the opening 5 SEALING THE WINDOW TO THE EXTERIOR WALL CLADDING When applying siding brick veneer or other exterior nish material leave adeq...

Page 7: ...INGLE HUNG AND DOUBLE HUNG DO NOT PAINT STAIN OR lNISH THE VERTICAL SASH EDGES ANY lNISH ON THE VERTICAL SASH EDGES MAY CAUSE THE SASH TO STICK IT IS OPTIONAL TO PAINT STAIN OR lNISH THE HORIZONTAL SA...

Page 8: ...or proper management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of a...