![Pelican PCL3 Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/pelican/pcl3/pcl3_owners-manual_1523108012.webp)
Rev L —
Calcite pH Neutralizer
©
2019
Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Page 1
1
Testing pH Levels in Water
1. Ensure your system is not in bypass mode.
2. Turn on the nearest faucet to the system (cold water only).
3. Let water run for 10 minutes.
4. After 10 minutes test the pH of the water at the same sink.
5. If pH test is lower than 7.0 let the system sit for 30 minutes and then go to the same sink and run
cold water for 10 minutes again and re-test.
Note: If you have a Natursoft system after the Calcite Tank, you must keep the Natursoft system
in bypass mode until the pH test is showing a pH level of the water to be between 7-11.
Maintenance
Calcite Tank Refill
When the tank is 1/3 full, consider replacing media.
How to refill calcite tank:
1.
Turn main water supply OFF.
2.
Bypass all other tanks except the calcite tank.
3.
Turn on the closest cold water faucet to relieve pressure. Wait until the faucet runs dry.
4.
Open side port on the calcite tank.
5.
Siphon out water down to calcite level.
6. Funnel in new calcite.
7.
DO NOT OVERFILL WITH CALCITE. Leave 12" from top of tank empty.
(877) 842-1635
PelicanWater