background image

© 

2019

 Enviro Water Solutions, Inc. 

3060 Performance Circle, Suite 2, DeLand, FL 32724

Figure 4

8.

Use the Hose Bib Assembly to connect your garden hose to the inlet side of the tank head.

9.

Slowly f

ill the tank with water until the water starts to flow out 

of 

the 

outlet side

. Turn water off and let

 

soak

 

for

 a

minimum of

 

48 hours.

10.

After 

a minimum of 

48 hours, turn the garden hose on 1/4 turn and rinse the tank for

 

30 minutes 

thru the

 

inlet

side 

to expel the

 

carbon fines

 

from the new media.

11.

Turn off the water.

12.

Disconnect Hose Bib Assembly from the inlet side and reconnect to the outlet side of the tank head.

13. Slowly fully open the garden hose and r

un water through the 

outlet

 side for 

3

 minute

s

 

to reset the carbon bed.

14.

Turn off the water.

15.

Remove the Hose Bib Assembly from the tank head and disconnect the garden hose.

Water

Whole House Water Filter

Garden

Hose

Hose Bib 
Assembly

Figure 

5

Bypass Valve

Bypass Valve

Head

Head

Tank

Tank

Quick-Connect

16.

Install the

 tank 

head back onto the Bypass Valve hand-tight all the way to the tabs. Turn the arrows on the

Bypass Valve back to their original positions.

Note

: Avoid high flow rates for the first 72 hours to avoid flow restriction caused by carbon blockage of the upper 

basket inside the carbon tank. 

Examples of high flow rate

 items

 are bathtubs, multi head showers, washing machines, dishwashers, hose spigots, 

multiple faucets or other water applications at one time. If you need to use these items in the first 72 hours simply 

put the carbon tank into bypass until you are finished with that application. High flow rates are 3 gallons per 

minute and above.

Examples of low flow rate

 items

 are 

toilet, faucet

 or

 shower.

INLET

OUTLET

INLET

OUTLET

INLET

OUTLET

PC600-R / PC1000-R, Rev E —

Pelican PC600/PC1000 Replacement Media

P

elican

W

ater.com

(877) 842-1635

Reviews: