background image

Verktygsboden Erfilux AB Källbäcksrydsgatan 1, SE-507 42 Borås

 © V

erkty

gsboden · Bor

ås · Sweden · 0120504-03

Summary of Contents for 513087

Page 1: ...Induction heater Induktionsv rmare Item No 513087...

Page 2: ...maren R k och r k fr n varmt brinnande lim r giftiga Anv nd alltid skyddsglas gon n r du anv nder induktionsv rmaren B r en l mpligt dubbelfilter mask damm och nga Anv nd v rmebest ndigahandskar n r d...

Page 3: ...ktion Induktionsv rmaren b r inte l mnas utan uppsikt n r den r p slagen F r att kyla effektivt och f rl nga livsl ngden p din induktionsv rmare se alltid till att det finns tillr cklig tillga ng p re...

Page 4: ...s av Lossa frysta rostiga korroderade skruvar och muttrar Steg 1 F st passande spiral spole till v rmaren 3 4 Steg 2 Tryck p ON 1 f r att starta v rmaren Steg 3 Placera spiralen runt muttern f rst f r...

Page 5: ...k ten att forts tta arbeta tills alla komponenter och spolen helt svalnat Koppla bort v rma ren fr n str muttaget Det kan demonteras reng ras och lagras Steg 1 N r arbetet r slutf rt sl pp brytaren f...

Page 6: ...Till gg 513834 20mm spiral Inkluderad 513835 26mm spiral Till gg 513836 32mm spiral Inkluderad 513837 37mm spiral Till gg 513838 43mm spiral Inkluderad 513839 50mm spiral Till gg 513840 U formad spole...

Page 7: ...mpa 3 L sknappar vred 4 Inf stning spole 5 Kylfl kt 6 Produkt varningsdekal 7 kropp hus 8 Adapter 9 Stickkontakt Krona Bucklans centrum Krona Krona Arbeta i en cirkul r r relse runt utsidan av kronan...

Page 8: ...v har f ljande harmoniserade standarder anv nts Standard EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 45 2002 A1 2008 A2 2012 EN 62233 2008 EN 61000 6 4 2007 A1 2011 EN 61000 6 2 2005 Notified body LC...

Page 9: ...g before using the induction heater Do not wear clothing containing metallic rivets waistbands pocket buttons or zippers when using the induction heater The heater can heat metal objects very quickly...

Page 10: ...ld not be left unat tended when it is switched on To cool efficiently and extend the life of your induction heater always make sure that there is sufficient access to clean air make sure that the valv...

Page 11: ...rn off Loosen frozen rusty corroded screws and nuts Step 1 Attach the appropriate coil coil to the heater 3 4 Step 2 Press ON 1 to turn on the heater Step 3 Place the coil around the nut first for a f...

Page 12: ...fan will continue to operate until all components and the coil have completely cooled down Dis connect the heater from the power outlet It can be disassembled cleaned and stored Step 1 When the work...

Page 13: ...Supplement 513834 20mm spiral Included 513835 26mm spiral Supplement 513836 32mm spiral Included 513837 37mm spiral Supplement 513838 43mm spiral Included 513839 50mm spiral Supplement 513840 U shape...

Page 14: ...14 1 ON Start 2 LED lamp 3 Lock buttons knobs 4 Fastening coil 5 Cooling fan 6 Product warning decal 7 body house 8 Adapter 9 Plug...

Page 15: ...owing harmonized standards have been applied Standards EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 45 2002 A1 2008 A2 2012 EN 62233 2008 EN 61000 6 4 2007 A1 2011 EN 61000 6 2 2005 Notified body LCIE...

Page 16: ...Verktygsboden Erfilux AB K llb cksrydsgatan 1 SE 507 42 Bor s Verktygsboden Bor s Sweden 0120504 03...

Reviews: