90PUNTPI11 – 90PUNTPI12 – 90PUNTPI13 – 90PUNTPI21 – 90PUNTPI22 – 90PUNTPI23
- 23 -
Six-monthly checks
Electrical system
q
clean all the contacts of the secondary circuit to remove corrosion with fine grain abrasive material
q
tighten all connections
q
check protection devices and overloads (thermostats)
q
check welding parameters and correct them if necessary
q
check tightness of the power, transformer and welding control unit terminals
Compressed air circuit
q
check the proper working order of the filter-regulator-gauge (FRG) unit
q
change any damaged connections
q
empty the air line filter
When the welding machine is not going to be used
If the welding machine is not going to be used for some time there are a few things that need doing to prevent damage:
q
lock the cylinder in the completely retracted position
q
if the machine has to be stored away protect it by wrapping it with a protective film
q
the welding machine must be stored in a dry place
q
protect unpainted parts from dirt and corrosion