CONCRETE CEILING

Drill two 1/4" (6 mm) dia. holes to a minimum depth of 

2.5" (64 mm). Attach ceiling plate (

C

) using two concrete 

anchors and #14 x 2.5" wood screws (

H

) as shown in 

Illustration A 

and

 1

2

, and 

(below). Tighten all fasteners.

IMPORTANT: It is the responsibility of the installer to 

verify that the ceiling will safely support the combined 

load of all attached hardware and components. 
Skip to step 3 for flush mount installation.
Skip to step 4 for extension column installation.

Illustration A

Installation to Concrete Ceilings

Use only PEERLESS ACC233 concrete anchors (sold separately). 

• 

FOR DIRECT ATTACHMENT TO LOAD BEARING 

CONCRETE ONLY! 

Concrete expansion anchors are 

not 

intended for attachment to concrete ceilings cov

-

ered with a layer of plaster, drywall, or other finishing 

material. 

WARNING

•  Tighten wood screws so that ceiling plate is firmly 

attached, but do not overtighten. Overtightening can 

damage the screws, greatly reducing their holding 

power.

•  Never tighten in excess of 80 in • lb (9 N.M.).
•  Make sure that mounting screws are anchored into 

the center of the studs. The use of an "edge to edge" 

stud finder is highly recommended.

WARNING

•  When installing Peerless ceiling mounts on a concrete ceiling, the ceiling must be at least 8" thick with a minimum 

compressive strength of 2000 psi. 

•  Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard

-

ware and components.

•  Never exceed the Maximum Load Capacity of 50 lb (27 kg).

WARNING

2

H

C

CONCRETE CEILING

concrete 

anchor

1

3

2

Drill holes and insert anchors (

H

).

Place plate (

B

) over anchors (

H

) and secure with screws (

E

).

Tighten all fasteners.

C

H

concrete 

surface

Summary of Contents for PJF2-UNV

Page 1: ...l 1 800 865 2112 Installation and Assembly Manual Vector Pro II Models PJF2 UNV PJF2 UNV S Maximum UL Load Capacity 50 lb 27 kg This product is intended for use with UL Listed products and must be ins...

Page 2: ...ructions or warnings call Peer less customer care at 1 800 865 2112 This product should only be installed by someone of good mechanical aptitude has experience with basic building construction and ful...

Page 3: ...x 3 8 spade thumb screw 1 560 1107 560 2107 G 10 32 x 3 8 serrated washer head socket pin screw 1 520 1151 520 2151 H 14 x 2 5 phillips hex head wood screw 2 5S1 015 C03 5S1 015 C04 J 25 ID x 56 OD x...

Page 4: ...ILING H C J It is the responsibility of the installer to verify that the supporting surface will safely support the combined load of all attached hardware and components WARNING 1 IMPORTANT Be sure to...

Page 5: ...ors are not intended for attachment to concrete ceilings cov ered with a layer of plaster drywall or other finishing material WARNING Tighten wood screws so that ceiling plate is firmly attached but d...

Page 6: ...e C and secure ball and socket mount A with a M5 x 10 mm socket pin screw E using security allen wrench U as shown in figure 3 2 NOTE Slotted set screw L is used to jam against the threads of the ball...

Page 7: ...ension column connector D Align slot in ball and socket mount A to one of the bottom holes in extension column connector D Insert and tighten one 10 32 x 3 8 socket pin screw K through extension colum...

Page 8: ...e B to projector using one screw N O P R or V for each channel as shown below Tighten all screws while keeping the center of gravity Be sure that adapter plate B is straight Adjust the feet of the cha...

Page 9: ...ding hole on the adapter plate this should line up automatically when the two are connect ed Push down and tighten the spring loaded captive screw to secure the adapter plate to the mount If not using...

Reviews: