ISSUED: 06-04-10  SHEET #: 120-9085-1

Installation to Double Wood Stud Wall

•  Installer must verify that the supporting surface will safely support the combined load of the equipment and all 

attached hardware and components.

•  Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the 

screws, greatly reducing their holding power.

•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder 

is highly recommended.

•  Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install

-

ers are responsible to provide hardware for other types of mounting situations. 

WARNING

fig. 2.1

fig. 2.2

A

STUD

F

A

2

Wall plate (

A

) can be mounted to four studs that are 16" apart. Use a stud finder to locate the edges of the studs. 

Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each 

stud’s center. Place wall plate on wall as a template. Level plate, and mark the center of the four mounting holes. 

Make sure that the mounting holes are on the stud center lines. Drill four 5/32" (4 mm) dia. holes 2.5" (65 mm) 

deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (

F

) as shown in figure 2.2.

Summary of Contents for DS-VL-H036

Page 1: ...350 lb 158 8 kg Installation and Assembly 36 Wall Plate Accessory Model DS VL H036 3215 W North Ave Melrose Park IL 60160 800 729 0307 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 06 04 10 SHEET 120 9085 1 ...

Page 2: ...s product was designed and intended to be mounted to the following supporting surfaces checked below with the hardware included in this product as specified in the installation sheet To mount this product to an alternative supporting surface contact Peerless customer care at 1 800 865 2112 This product was designed to be installed on the following wall construction only WALL CONSTRUCTION ADDITIONA...

Page 3: ...ACK VIEW Skip to step 2 on page 5 for installation to solid concrete or cinder block walls Some parts may appear slightly different than illustrated Before you begin make sure all parts shown are included with your product A B D E F C PARTS LIST Description Qty Part A wall plate 1 145 1141 B M4 x 12 mm socket pin serrated washer head screw 8 510 1079 C 8 mm concrete anchor 4 590 0320 D wall plate ...

Page 4: ...ovided is for attachment of mount through standard thickness drywall or plaster into wood studs Install ers are responsible to provide hardware for other types of mounting situations WARNING fig 2 1 fig 2 2 A STUD F A 2 Wall plate A can be mounted to four studs that are 16 apart Use a stud finder to locate the edges of the studs Use of an edge to edge stud finder is highly recommended Based on the...

Page 5: ...o concrete covered with plaster drywall or other finishing material If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 custom fasteners must be supplied by installer WARNING Tighten screws so th...

Page 6: ... trademarks of their respective owners Installing Multiple Wall Plates and Screens ACC DSV240 SOLD SEPARATELY Install adapter brackets sold separately to screens using adapter bracket instructions Multiple wall plates and adapter brackets sold separately can be used to create multiple screen displays WALL PLATE MAY APPEAR DIFFERENT THAN ILLUSTRATED 3 ...

Reviews: