59
ENGLISH |
MODE3 CONFIG
HELP SET:OFF
• Enable (
ON
) or disable (
OFF
) activation of the second electric pump (safety)
• This parameter is used to enable the second electric pump with a program-
mable time (even if there is no second input IN2)
MODE3 CONFIG
HELP TIME:5m
• Safety electric pump activation time
Default
5 min
Range
0-60 min
Step
1 min
Configuring MODE 4
SELECT
MODE CONFIG
• Press the
key to confirm the choice and enter the submenu.
9
MODE CONFIG
MODE:1
• Press the
key to enter the submenu and change mode.
6
9
MODE:4
• Press the
or
key to select mode 4
(from modes 1 to 6)
• Press the
key to confirm the choice of MODE:4
• Press the
key to continue with the configuration
9
MODE CONFIG
SETUP
• Press the
key to enter the mode 4 configuration submenu
9
MODE4 CONFIG
IN1:ON
• Enable (
ON
) or disable (
OFF
) input IN1
• This input is used to start a single electric pump according to the al-
ternating logic
MODE4 CONFIG
IN2:ON
• Enable (
ON
) or disable (
OFF
) input IN2
• This input is used to start the second electric pump according to the
alternating logic, or to start both electric pumps simultaneously
MODE4 CONFIG
LOGIC:ALTERN.
• If the system has two electric pumps, enable (
ALTERN.
) or disable
(
SINGLE
) the alternating logic.
MODE4 CONFIG
HELP SET:OFF
• Enable (
ON
) or disable (
OFF
) activation of the second electric pump
(safety)
• This parameter is used to enable the second electric pump with a pro-
grammable time (even if there is no second input IN2)
MODE4 CONFIG
HELP TIME:5m
• Safety electric pump activation time
Default
5 min
Range
0-60 min
Step
1 min
Continued
Summary of Contents for E1 MONO
Page 2: ......