USING SOLAR PANELS TO CHARGE THE E1000 PRO

1. DC5521 Charging Port: 

PV/DC 12V~18V, 100W maximum; VOC(open circuit voltage) of solar panel must be than 25V;

2. GX16MF-5 Charging Port: 

PV(operating voltage) range  32V~95V, 400W maximum; VOC(open circuit voltage) of solar 

    panel/array must be than 95V, otherwise, it will damage the unit! Do not wire more than two 36V(AKA 24V) solar 

    panels in series. (36V stands for Vmp, the operating voltage, of the solar panel)

3. If you have any questions, Please feel free to contact us:[email protected]

E1000

PRO

DC5521 Charging Port: 

PV12V~18V-100W Maximum Input

GX16MF-5 Charging Port:

PV32~95V-400W Maximum Input

Summary of Contents for E1000 PRO

Page 1: ...Please read the user manual thoroughly before using support pecron com USER MANUAL E1000 E1000 PRO...

Page 2: ...FUNCTION INTRODUCTION DC 12V 18V Charging Port AC 100V 120V Switch Wireless Charger LCD Display DC12V Auxiliary Output DC 12V USB Wireless Switch DC 32V 95V Charging Port DC12V 5525 Output USB A USB...

Page 3: ...Protections Over Voltage Overheat Overload Short Circuit Self Recovery Temperature 0 45 32 F 113 F Charging 20 45 4 F 113 F Discharging Charging Time Minimum 2H to 100 AC 3 5H to 100 E1000 PRO OUTPUT...

Page 4: ...s When overload occurs the AC Overload Alarm Icon will flash and the unit will stop working Temperature Alarm Icon E1000 PRO can power your devices at temperatures ranging from 20 45 If your working t...

Page 5: ...CHARGE TIME The solar charging time depends on weather conditions E1000 PRO has a built in MPPT charge controller that supports 32 95V 15A PV charging up to 400W 200W 1 6 7 Hours Recommended 400W 2 3...

Page 6: ...95V 400W maximum VOC open circuit voltage of solar panel array must be than 95V otherwise it will damage the unit Do not wire more than two 36V AKA 24V solar panels in series 36V stands for Vmp the o...

Page 7: ...SING SOLAR PANELS TO CHARGE THE E1000 PRO 36V 36V MC4 Solar Charging Cable 1 pecron 200W 1 Using the pecron 200W 36V 1 200W to charge the E1000 PRO 36V is the operating voltage of the solar panels 36V...

Page 8: ...Power Watts Q5 Can I use the E1000 PRO indoors and charge the E1000 PRO indoors A Yes the E1000 PRO is safe to use indoors Q6 Does E1000 Pro have built in MPPT charge controller A Yes there are two i...

Page 9: ...the temperature is too low the performance of the battery will be seriously degraded and it may even fail to meet the normal use requirements Please read the user manual thoroughly before using this...

Page 10: ...ce this device with care to prevent the product from being damaged due to fall off If the product is damaged due to fall off please turn off the unit immediately and place it in an open area keep away...

Page 11: ...ranty does not apply to Misused abused modified damaged by accident or used for anything other than normal consumer use as authorized in Pecron s current product literature CUSTOMER SUPPORT support pe...

Page 12: ...POWER IT POSSIBLE www pecron com support pecron com...

Reviews: