STARTING PEBBELL 2
17
To turn off this function, send command M0 to the device. The minimum setting is 100 meters.
⑲
MOTION ALARM
Send SMS command: V1,xx S/M/H (Default V0)
NOTE: No spaces in between, S stands for seconds, M stands for minutes, H stands for hours, xx
stands for the time you set and must be given in two digits.
Example: V1,05M
If the user turns on this function, the device will detect motion every 5 minutes and will send an
SMS warning alarm to all registered phone numbers.
To turn off this function, send command V0 to the device.
⑳
FALL DETECTION
Send SMS command: FL1 (Default FL0)
The device must sense both the impact and the angle of the fall, after which it must remain in a
lying position for at least 10 seconds. After this, the device will raise alarm. A simple fall may
cause harm, but the fall sensor might support you to get immediate help without missing any
important moment.