REA R PANEL
The IEC power cord that is correct for your locale
should be included
with your unit. There are 2 available units, one for 120V operation and
another for 240V operation. Please note proper voltage operation for
your unit and locale.
ON-OFF SWITCH (1)
This rocker switch supplies AC power to the PBK12
FM
when
switched to the ON position. The ON position is with the top side
of
the switch pushed
"
in"
o
r nearly flush with the rear panel.
FUSE (2)
The unit is AC power line fuse protected from overloads
and fault conditions with a slow-blow 5 x 20mm 250V fuse.
This fuse is located within the base of the IEC power cord
connector (2), just below the IEC connector blades. If the fuse
fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND
VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT AND TO
PREVENT VOIDING THE WARRANTY!
The fuse in the Peavey PBK12
FM
can be replaced with a time-
delay type 5 x 20 mm size 250V rated fuse.
For 110-120VAC operation, a fuse rated at 3.15 amps
and
250V should be used, which conforms to the
international fuse classification "T3.15A
L
".
For
the
220-240VAC
unit
, a fuse rated at
1.6
amps and 250V
should be used, which conforms to the
international fuse
classification "T
1
.
6
A
L
".
If the unit continues to blow replacement fuses, do not keep replacing them, it should be taken to a qualified
service center for repair.
To replace the fuse, be sure to remove the IEC power cord from the IEC socket. The fuse holder tray is located
beneath the IEC socket cavity. Pry the fuse holder tray out with a small flat blade screwdriver placed under the
center of the top edge of the fuse tray, and gently lever the fuse tray out. The fuse is held in a clip in the fuse tray,
and should be removed and replaced with a fresh 5 X 20mm 250V type fuse of the appropriate current rating.
T
hen, once the fresh fuse has been put in place, re-insert the fuse tray into the IEC connector assembly, making
sure that the voltage range selection is correct (see above section) and make sure it is fully seated and flush with
the outside of the IEC connector assembly.
IEC POWER CORD CONNECTION (3)
This receptacle is for the IEC line cord (supplied) that provides AC power to the unit. It is very important that
you ensure the PBK12
FM
has the proper AC line voltage supplied.
Please read this guide carefully to ensure your personal safety as well as the safety of your equipment. Never
break off the ground pin on any equipment. It is provided for your safety. If the outlet used does not have a
ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To
prevent the risk of shock or fire hazard, always be sure that the mixer and all other associated equipment are
properly grounded.
Unit shown is
120V