background image

IMPORTANT SAFETY INSTRUCTIONS

  WARNING:

 When using electrical products, basic cautions should always be followed, including the following:

1. 

Read these instructions. 

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7. 

Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) 
that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is 
provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet. 

10. 

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point 
they exit from the apparatus.

11. 

Only use attachments/accessories provided by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a 
cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in 
any way, such as when power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15. 

Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power 
supply of the type marked on the unit adjacent to the power supply cord.

16. 

If this product is to be mounted in an equipment rack, rear support should be provided.

17. 

Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your 
plug‚ proceed as follows:

 

a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth 
symbol‚ colored green or colored green and yellow.

 

b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.

 

c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.

18. 

This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place objects 
containing liquids, such as vases, upon the apparatus.

19. 

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in suscep-
tibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise 
for a sufficient time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the 
following permissible noise level exposures:

 

 

Duration Per Day In Hours 

Sound Level dBA, Slow Response

 

 

90

 

 

92

 

 

95

 

 

97

 

 

100

 

 

1 1⁄2 

102

 

 

105

 

 

1⁄2 

110

 

 

1⁄4 or less 

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Earplugs or protectors to 
the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if 
exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is 
recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be 
protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Summary of Contents for KOSMOS V2

Page 1: ...www peavey com Kosmos v2 Spectrum Enhancement System Operating Manual...

Page 2: ...est utilis dans ce manuel pour indiquer l utilisateur la pr sence d une tension dangereuse pouvant tre d amplitude suffisante pour constituer un risque de choc lectrique Ce symbole est utilis dans ce...

Page 3: ...nnect only to a power supply of the type marked on the unit adjacent to the power supply cord 16 If this product is to be mounted in an equipment rack rear support should be provided 17 Note for UK on...

Page 4: ...runtergefallen ist 15 Der Erdungsstift darf nie entfernt werden Auf Wunsch senden wir Ihnen gerne unsere kostenlose Brosch re Shock Hazard and Grounding Gefahr durch elektrischen Schlag und Erdung zu...

Page 5: ...etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond pas au guide de la prise secteur proc dez comme suit a Le connecteur vert et jaune doi...

Page 6: ...ctrocuci n y Toma a Tierra Conecte el aparato s lo a una fuente de alimentaci n del tipo marcado al lado del cable de alimentaci n 16 Si este producto va a ser enracado con m s equipo use alg n tipo d...

Page 7: ...ligent phase synced subharmonics that don t overpower existing material Dynamic source tracking yields tight clean bass sounds Subharmonic activity indicator shows processing status A specially tuned...

Page 8: ...ontrol adds a specific band of bass frequencies natural not synthesized to the bass enhance ment mix It is voiced to compliment the subharmonics and is used to even out the low end balance This contro...

Page 9: ...th the letter N or colored black 3 The wire that is colored brown must be connected to the terminal that is marked with the letter L or colored red Subwoofer Output This 1 4 TRS electronically balance...

Page 10: ...PUT L MONO SUBHARMONICS LOW DAMPING LEFT LEVEL LEVEL RIGHT LEFT RIGHT INPUT AMPLIFIER L MONO RIGHT RIGHT SUB WOOFER SERVO BAL DRIVER DRIVERS OUTPUT LEFT RIGHT SUB WOOFER SERVO BAL BAL OUTPUTS BAL INPU...

Page 11: ...t Net 7 1 lbs 3 22 kg Shipping Weight 8 7 lbs 3 95 kg THD N 10Hz 80K Hz BW Power Requirements 8 Watts 120VRMS 50 60 Hz 8 Watts 230VRMS 50 60 Hz Process Mode 003 Bypassed 001 Signal to Noise Crosstalk...

Page 12: ...s de graves que ni sobrecargan el equipo instalado Canal din mico de pistas acopladas estrechamente limpia los graves Indicador estatus de Enfatizadores de Graves Un circuito de baja freceuncia especi...

Page 13: ...sintetizada a la mezcla de graves Est planeada para complementar los graves arm nicos y se usa para equilibrar la salida de bajas frecuen cias balanceadas Este control se puede considerar como un ajus...

Page 14: ...letra N o de color negro 3 El cable de color marr n debe ser conectado a la terminal con la letra L o de color rojo Salida Subgrave Esta salida de 1 4 TRS electronicamente balanceada se puede usar o...

Page 15: ...PUT L MONO SUBHARMONICS LOW DAMPING LEFT LEVEL LEVEL RIGHT LEFT RIGHT INPUT AMPLIFIER L MONO RIGHT RIGHT SUB WOOFER SERVO BAL DRIVER DRIVERS OUTPUT LEFT RIGHT SUB WOOFER SERVO BAL BAL OUTPUTS BAL INPU...

Page 16: ...7 1 lbs 3 22 kg Shipping Weight 8 7 lbs 3 95 kg THD N 10Hz 80K Hz BW Potencia Requerida 8 Watts 120VRMS 50 60 Hz 8 Watts 230VRMS 50 60 Hz Modo Proceso 003 Con circunvalaci n 001 Se al a Ruido Crossta...

Page 17: ...teur inteligent de Sous Harmoniques graves sans surgarge de puissance du signal REPERAGE DYNAMIQUE Precis des sons de basses du signal source Indicateur d activite SubharmoniQUE indiquant l ETAT de tr...

Page 18: ...une bande de fr quence basse sp cifique naturel non synth tique au mix de majoration des graves Ceci est accord pour agr menter les subharmoniques et pour egaliser l quilibre du bas du sp ctre Ce cont...

Page 19: ...ub Woofer Elles sont galement doubl es en parall le par un connecteur XLR chacunes Les sorties XLR et Jack d un m me canal ne doivent pas tre utilis es simultan ment tant donn que la sym trisation du...

Page 20: ...ght Net 7 1 lbs 3 22 kg Shipping Weight 8 7 lbs 3 95 kg THD N 10Hz 80K Hz BW Energie requise 8 Watts 120VRMS 50 60 Hz 8 Watts 230VRMS 50 60 Hz Mode Process 003 D riv 001 Signal vers Bruit Diaphonie 75...

Page 21: ...dene Signal nicht unterdr cken Dynamisches Tracking des Quellsignals liefert dichte und saubere Bassfrequenzen Eine Anzeige zeigt den Bearbeitungsstatus der Aktivit t der subharmonischen Frequenzen an...

Page 22: ...mpfung gibt es einen niedrigeren Spitzenwert der Durchschnittspegel kann je nach Quelle jedoch h her sein sodass der Pegel der subharmonischen Frequenzen eventuell verringert werden muss Low Freq Mit...

Page 23: ...ngsstift bzw Erdkontakt am Stecker des Netzkabels darf auf keinen Fall entfernt oder abgeschnitten werden Das Ger t wird mit einem Netzkabel geliefert das die korrekten Werte aufweist Sollte das Kabel...

Page 24: ...rdr ckung von Brummen und Rauschen durch das Ger t beeintr chtigen Mono Mit diesem Schalter wird der Kosmos v2 auf Monobetrieb umgestellt Dazu wird die Left Monoeingangsklinke als Quelle eingesetzt un...

Page 25: ...Gesamtklirrfaktor plus Rauschen 10 Hz bis 80 kHz BW Leistungsbedarf 8 Watt an 120 V RMS 50 60 Hz 8 Watt an 230 V RMS 50 60 Hz Bearbeitungsmodus 0 003 Mit Bypass 0 001 Rauschabstand Crosstalk 75 dB be...

Page 26: ...eceipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 Ship the defective item prepaid to Peavey Electronics Corporation International Serv...

Page 27: ...27 NOTES...

Page 28: ...Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5365 FAX 601 486 1278 www peavey com 2005 80305201 Printed in the USA...

Reviews: