background image

STEREO MODE   BALANCED INPUTS

Ground Lift

Defeated

Can be used as

outputs to patch to

other power amp

inputs provided

stereo patch cords

are used

Mode Switch

In Stereo Position

Speakers

 

 

     

 

   

Speakers

Set impedance
selector switch

to match load

impedances

t

Right

output

From Mixer

t

Left

output

From Mixer

If hum is

Can be used as

 in

 to patch to

system, the

other 

 amp

STEREO MODE   UNBALANCED INPUTS

ground lift

inputs with single

feature might

conductor shielded

eliminate it

patch cords

Mode Switch

I

In Stereo Position

I

Set impedance
selector switch

to match load

impedances

Right

output

From Mixer

Left

output

From Mixer

TWO CHANNEL MONO MODE

If hum is present in

system, the ground lift

feature might eliminate it

I

Mode Switch

In Stereo Position

I

To Second

Set of

To First Set 

Set impedance
selector switch

I

Speakers

of Speakers

to match load

impedances

BRIDGE MODE

If hum is present in

system, the ground lift

feature might eliminate it

I

Mode Switch

In Bridge Position

System Load

4 ohm minimum

Set impedance selector

switch to match load

 indicates not used

output

From 

Summary of Contents for CS 200X

Page 1: ......

Page 2: ...IA Para evitar corrientazos o peligro de incendio no deje expuesto a la lluvia o humedad este aparato Antes de usar este aparato lea mas advertencias en la guia de operation A Ce symbole est utilise pur indiquer a l utilisateur la presence a l interieur de ce produit de tension non isolee dangereuse pouvant tre d intensite suffisante pour constituer un risque de choc Clectrique A Ce symbole est ut...

Page 3: ...0X contains dual calibrated detented input sensitivity controls a mains power switch an LED power indicator and dual LED DDT activation indicators The rear panel of the CS 200X has dual paralleled l 4 input jacks dual paralleled l 4 output jacks and 5 way binding posts for each channel Additionally the back panel has the stereo bridge select the impedance select and the ground lift switches DDTTM ...

Page 4: ...nt is just asking for trouble HIGH Z INPUT JACKS 7 Two parallel bridged input jacks are provided for each channel This allows for one to be used as a conven tional input and the other to be used simultaneously as a line out Y cord to connect to another input jack on this amplifier or to other equipment All these l 4 jacks are stereo RING TIP AND SLEEVE and the input circuitry of the CS 200X is ful...

Page 5: ...conditions can always be considered safe However sustained operation at loads below the impedance selector switch setting per channel and below twice that of the impedance selector switch setting in BRIDGE mode could result in temporary amplifier shut down due to the thermal limits and or the internal fault circuitry A chart listing the allowable loads for the various impedance selector values is ...

Page 6: ...onic equipment is operated the longer its useful service life STUDIO AND HOME INSTALLATION In most low to medium power applications the CS 200X can be mounted in any configuration It is desirable for if at all possible the unit be located at the top of an equipment stack This will prevent possible overheating of any sensitive equipment by the hot air rising from the power amplifier As a general ru...

Page 7: ...ntly reduces the potential of loudspeaker degradation and damage The DDT system is an automatic hands off approach to the problem of power amplifier clipping Since the CS 200X power amplifier uses a circuit breaker for over current protection the DDT compression system plays even a more important roll in continuous performance by preventing each channel from clipping and overload Con tinuous opera...

Page 8: ...MS 4 ohms 16 ohms 20 Hz to 20 kHz 0 07 THD 150 W RMS 8 ohms 32 ohms 20 Hz to 20 kHz 0 05 THD 150 W RMS 16 ohms Distortion Typical Value Stereo mode both channels driven 20 Hz to 20 kHz rated power load Below 0 1 4 ohms 0 07 8 ohms 0 05 16 ohms Input Sensitivity Impedance Input attenuator set FCW rated power load 0 7 V RMS 3 dBV 4 ohms 1 0 V RMS 0 dBV 8 ohms 1 4 V RMS 3 dBV 16 ohms 20 K ohms 28 dB ...

Page 9: ...t inputs with single feature might conductor shielded eliminate it patch cords Mode Switch I In Stereo Position I Set impedance selector switch to match load impedances t Right output From Mixer t Left output From Mixer TWO CHANNEL MONO MODE If hum is present in system the ground lift feature might eliminate it I Mode Switch In Stereo Position I To Second Set of To First Set 1 Set impedance select...

Page 10: ... limrted warrantres and the other terms and condrtions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return It FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action Including negligence IS limrted to the actual damages...

Page 11: ...ased household cleaner if necessary Disconnect unit from power supply before cleaning Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The...

Page 12: ...Features and specifications subject to change without notice A Peavey Electronics Corporation 711 A Street Meridian MS 39301 U S A 601 483 5365 I Fax 486 1278 01994 80301992 Printed in U S A 4196 ...

Reviews: