PLEASE READ BEFORE PROCEEDING WITH INSTALLATION 

FAILURE TO READ AND CONSIDER SAFETY INSTRUCTIONS IN THIS MANUAL OR ON 

BEST CONTROL MAY RESULT IN PERSONAL INJURY OR SERIOUS DAMAGE TO PIPING 

OR FIXTURES ! 

Hazardous pressure. 
  

Under certain conditions, submersible pumps can develop extremely high pressure. Install a 
pressure reducing valve to limit pressure to safe levels for application. Be sure well is   

equipped with a pressure relief valve. 

Do not allow pump,  BEST CONTROL, piping, or any other system component containing water to 

freeze. Freezing may damage system, leading to injury or flooding. Allowing BEST CONTROL or 
system components to freeze will void warranty. 

Hazardous voltage.  

Can shock, burn or cause death. 

Install ground and wire BEST CONTROL according to local code and National Electrical Code 
requirements. 

Depressurize the system and disconnect power supply before installing or servicing BEST CONTROL. 

Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency 
and BEST CONTROL voltage and frequency. 

Install BEST CONTROL according to all plumbing, pump and well code requirements. 

Pipe joint compound can cause cracking in plastic. Use only Teflon tape when sealing joints in plastic pipe or 

connecting pipe to thermoplastic pumps and BEST CONTROL. 

For threaded conduit opening - To be used with UL Listed or Recognized, liquid-tight non-metallic (plastic) 

conduit fittings. 

The manufacturer is not responsible or liable for damage due to improper 
installation or use

This is the safety alert. When you see this symbol in this manual, look for one of the following 

signal words and be alert to the potential for personal injury. 

Warns about hazards that 

will

 cause serious personal injury, death or major property 

damaged if ignored. 

Warns about hazards that 

can

 cause serious personal injury, death or major property 

damaged if ignored. 

- 2 - 

Summary of Contents for PCBC16F16S

Page 1: ...Built in pressure and flow switch Can be used with or without pressure tank e m i t d n a e c a p s s e v a s n o i t a l l a t s n i e l p m i S e v l a v k c e h c n i t l i u B d e r i u q e r e c...

Page 2: ...nnections 9 Installation wiring diagram 115 VAC 2 wire pumps up to 16 FLA 9 Installation wiring diagram 230 VAC 2 wire pumps up to 20 FLA 10 Installation wiring diagram 230 VAC 3 wire pumps up to 20 F...

Page 3: ...m and disconnect power supply before installing or servicing BEST CONTROL Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency and BEST CONTROL voltage and...

Page 4: ...p opened Green Power on light and yellow Pump on should display This indicates system is operating properly If red Failure light comes back on refer to Troubleshooting Guide OPERATION TROUBLESHOOTING...

Page 5: ...he six screws from the cover Line voltage and pump wires to the BEST CONTROL should be supplied through liquid tight nonmetallic conduit fittings rated NEMA 12 or UL type 12 to achieve NEMA Type 12 en...

Page 6: ...PS 5 If pressure exceeds 145 psi install a pressure reducing valve ABOVE GROUND PUMP BEST CONTROL can be installed on above ground and submersible pumps for residential domestic irrigation and booster...

Page 7: ...vel Do not install any tap or tee between the pump and the BEST CONTROL Install a pressure reducing valve between pump and BEST CONTROL when maximum pressure generated by the pump exceeds 145 psi Inst...

Page 8: ...st tap must not exceed 70 feet BEST CONTROL unit operates from min 32 psi to the max pressure generated by the pump C BEST CONTROL preset cut in pressure 42 psi model Max pressure generated by the pum...

Page 9: ...rol 1 x 1 psi loss 3 5 9 14 19 Best control 1 x 1 psi loss 2 2 3 5 8 10 12 Best control 1 x 1 psi loss 2 2 3 4 6 7 8 Pressure Loss Chart with a bypass application with Best control 1 PRESSURE LOSS BYP...

Page 10: ...licable BEST CONTROL wiring diagram If pump motor FLA exceeds BEST CONTROL rating use magnetic starter wiring diagram for the applicable voltage see pages 12 13 Use Copper Conductors only Use 140 167...

Page 11: ...INSTALLATION WIRING DIAGRAM 230VAC 2 WIRE PUMPS UP TO 20 FLA INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS UP TO 20 FLA 10...

Page 12: ...ase applications Remember match coil voltage on contactor with BEST CONTROL voltage Either 115V or 230V coils may be used Use of magnetic starter to avoid damage to the device is determined by pump mo...

Page 13: ...R 230 VAC THREE PHASE 3 WIRE PUMPS INSTALLATION WIRING DIAGRAM 460VAC For 460Vac motors use magnetic starter to avoid damage to BEST CONTROL 12 For 208Vac or 230Vac three phase motors use magnetic sta...

Page 14: ...OVERALL DIMENSIONS 13 INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS EXCEEDING 20 FLA...

Page 15: ...ill not operate WARNING Do not turn on power until the box cover has been securely fastened 4 Install the new electronic box and t ighten the three screws Do not overthighten or damage to threads may...

Page 16: ......

Reviews: