8. VOLTAGE CHANGE PROCEDURE
8.1 VOLTAGE CHANGE PROCEDURE FOR IRONJ 05 - IRONJH 05 - IRONJ 07
8.2 VOLTAGE CHANGE PROCEDURE FOR IRONJ 10 - IRONJ 15
9. PEARL MOTOR DATA
10. PEARL MOTOS ARE PRE-WIRED BY HP:
- 1/2 wired for 115 Volt.
- 3/4 - 1 1/2 HP wired for 230 Volt.
MOTOR
PART #
HP
VOLTS
PHASE SERVICE
FACTOR
Pump MAX.
LOAD AMPS
IRON J-05
0.5
115V / 230V
1
1.90
10.8 / 5.4
IRON J-07
0.75
115V / 230V
1
1.90
14.2 / 7.1
IRON J-10
1 115V / 230V
1
1.75
16.6 / 8.3
IRON J-15
1.5
115V / 230V
1
1.60
21 / 10.5
Unscrew and
remove the cover.
Check the voltage
set from factory.
If you want to
power the pump
with 115 V,
rotate the plug
to 115 V.
Close the cover.
If you want to
power the pump
with 230 V,
rotate the plug
to 230 V.
1
4
5
2
3
Unscrew and
remove the cover.
Remove the
Voltage plug.
Install the Voltage
Plug aligning the
arrow with the
voltage needed.
Choose connection
for 115 V.
Reinstall the cover
back.
Choose connection
for 230 V.
1
4
5
6
2
3
WATER SYSTEMS
PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413