8. VOLTAGE CHANGE PROCEDURE

8.1 VOLTAGE CHANGE PROCEDURE FOR IRONJ 05 - IRONJH 05 - IRONJ 07

8.2 VOLTAGE CHANGE PROCEDURE FOR IRONJ 10 - IRONJ 15

9. PEARL MOTOR DATA

10. PEARL MOTOS ARE PRE-WIRED BY HP:

- 1/2 wired for 115 Volt.
- 3/4 - 1 1/2 HP wired for 230 Volt.

MOTOR 

PART #

  HP                   

VOLTS 

PHASE                 SERVICE 

FACTOR  

Pump MAX. 

LOAD AMPS

IRON J-05

0.5 

115V / 230V

1.90 

10.8 / 5.4

IRON J-07

0.75 

115V / 230V

1.90

14.2 / 7.1

IRON J-10

1     115V / 230V

1.75 

16.6 / 8.3

IRON J-15

1.5 

115V / 230V

1.60 

21 / 10.5

Unscrew and

remove the cover.

Check the voltage 

set from factory.

If you want to 

power the pump 

with 115 V, 

rotate the plug 

to 115 V.

Close the cover.

If you want to 

power the pump 

with 230 V, 

rotate the plug 

to 230 V.

1

4

5

2

3

Unscrew and

remove the cover.

Remove the 

Voltage plug.

Install the Voltage 

Plug aligning the

arrow with the

voltage needed.

Choose connection

for 115 V.

Reinstall the cover

back.

Choose connection

for 230 V.

1

4

5

6

2

3

WATER SYSTEMS

PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090  FAX: (954) 889 0413

www.pdwatersystems.com

 |                       pdwatersystems

Summary of Contents for Iron Jet IRONJ 05

Page 1: ...ee Chart 1 for specific information Always disconnect the power source before installing or servicing the pump This motors come with an automatic thermal overload protection this feature may allow an overheated pump to restart suddenly Water and electricity can be dangerous if certain precautions are not adhered to This pump is designed to operate in a safe way in a water environment however impro...

Page 2: ... other male connection into the female end of the bushing Failuretofollowtheseguidelinesmaydamagethebushing Caution should be taken to not cross thread the bushing 3 FLUSHING If the pump discharge line is connected to pressure tank or house service disconnect it and flush and clean the system by Time delay fuses and circuit breakers Single Phase For distances of 100 feet and over from meter to mot...

Page 3: ... pump discharge to pressure tank and pressure tank to house plumbing 7 After piping is completed and motor is properly wired remove the priming plug on top of pump and fill pump with clean water Allow time for air in the system to escape and refill pump if necessary before replacing the priming plug Start motor and the unit should operate If it does not it may be necessary to reprime 8 When unit h...

Page 4: ...5 16 6 8 3 IRON J 15 1 5 115V 230V 1 1 60 21 10 5 Unscrew and remove the cover Check the voltage set from factory If you want to power the pump with 115 V rotate the plug to 115 V Close the cover If you want to power the pump with 230 V rotate the plug to 230 V 1 4 5 2 3 Unscrew and remove the cover Remove the Voltage plug Install the Voltage Plug aligning the arrow with the voltage needed Choose ...

Reviews: