Pearl CEP-C2P Installation And Operating Instructions Download Page 2

1

2

3

5

6

8

9

10

11

12

13

4

7

14

15

16

17

18

6. PRODUCT STRUCTURE

POS. PART

Pump body

2 Impeller

Mechanical seal

Seal holder

Motor support

6 Bearing

7 Rotor

Spring washer

Fan cover

7. PIPELINE INSTALLATION

This product should be installed and 

maintained by personnel who is proficient in 

this manual and has special qualifications.

Installation and operation should be in 

accordance with local regulations and 

recognized operation standards.

Install pipelines properly as stipulated in the 

manual and  eanwhile conduct frost protection 

measures for the pipeline.

7.1 For pump installation, the inlet pipe should be as short as 

possible with the least turnings.The pump should be installed 

in ventilated and dry environment. It could be installed outside, 

provided having proper covering to prevent rain and wind.

7.2 For pipeline use, valves should be installed on inlet and 

outlet pipelines and the inlet pipeline should be installed with 

check valve.

10 Fan

11 

End plate

12 

Cable holder

13 Capacitor

14 

Capacitor box

15 

Terminal board

16 Stator

17 Bracket

18 

O-sealing ring

5.5. Keep the pump in 

ventilation.

5.6. In case ambient tempera-

ture is lower than 4 or the 

pump is not used for a long 

time, empty liquid the pipeline 

system to avoid ice cracking 

of the pump chamber. Do not 

operate the pump for a long 

time without water in it.

5.7. The pumped liquid 

maybe hot and under high 

pressure, before moving and 

demounting the bump, valves 

in both sides of the bump 

should be turned off first and 

then empty liquids in the 

pump and pipelines so as not 

to be scalded.

5.8. Do not transfer any 

inflammable, explosive or 

gasified liquids that beyond 

the stipulation.

5.9. Ensure the pump will not 

be accidently turned on while 

installing and maintaining; if 

not used for a long time, cut 

off the power first and then 

turn off valves in inlet and 

outlet of the pump.

5.10. Power supply should be 

in accordance with the 

voltage stated in the 

nameplate. If not used for a 

long time, put the pump in 

dry, ventilated and cool place 

under room temperature.

Max. water temperature: + 60
Min. Water temperature: +4 

Reviews: