Button Function Operation
Hold Function
The hold function freezes the reading in the display. Press the HOLD
key momentarily to activate or to exit the hold function
Backlight
Press the key for to turn on the display backlight function. The
backlight will automatically turn off after 15 seconds.
Earth resistance
Range
Resolution
Accuracy
20
0,01
+/-(2%+10 dgt.)
200
0,1
+/-(2%+ 3 dgt.)
2000
1
+/-(2%+ 3 dgt.)
Test current: 2 mA
Test frequency: 840 Hz
Earth voltage
Range
Resolution
Accuracy
200 V
0,1 V
+/-(3%+3 dgt.)
Ohm
Range
Resolution
Accuracy
Overload
Protection
200 k
0,1 k
+/-(1%+ 2 dgt.)
250 V
rms
DC Voltage
Range
Resolution
Accuracy
Input
Impedance
Overload
Protection
1000 V 1 V
+/-(0,8%+3 dgt.)
10 M
1000 V
rms
AC Voltage (40 Hz ~ 400 Hz)
Range
Resolution
Accuracy
Input
Impedance
Overload
Protection
750 V
1 V
+/-(1,2%+10dgt.) 10 M
750 V
rms