Cleaning the cabinet
Clean only with a damp, soft cloth and a commercially available mild
household cleanser. Ensure that no water gets inside the equipment to
prevent possible shorts and damage to the equipment.
1. Features
- Capable of measuring earth voltage
- 2 mA measuring current permits earth resistance tests without
tripping earth leakage current breakers in the circuit under test
- Battery operated
- Battery life indicator
- Data-Hold-Function
2. Specifications
Measuring ranges
Earth resistance:
0~19,99
Ω
(0,01
Ω
)
0~199,9
Ω
(0,1
Ω
)
0~1999
Ω
(1
Ω
)
Earth voltage: 0 - 200 V AC, 50/60 Hz
Accuracy:
Earth resistance:
± 2 % + 3 dgt. at 200/2000
Ω
± 2 % + 0,3
Ω
at 20
Ω
Earth voltage: within ± 3 % rdg. + 2 dgts.
Measurement
Earth resistance by constant current
System:
inverter. 820 Hz approx. 2 mA
Safety Standard
meet EN-61010-1, Safety requirements
installation CAT III/300 V
Low battery indication
“
” symbol appears on the display
Data Hold indication
“DH” symbol appears on the display
Over range indication
“1”
Display
3 ½ digit LCD display (2000 counts)
-12-