Safety Notices

Peak Scientific Instruments cannot anticipate every possible circumstance which may 

represent a potential hazard. The warnings detailed within this document detail the 

most known potential hazards, but by definition cannot be all inclusive. If the user 

employs an operating procedure, item of equipment or a method of working which 

is not specifically recommended by Peak Scientific, the user must ensure that the 

equipment will not be damaged or become hazardous to persons or property.

Symbols

This document uses the following symbols to highlight specific areas important to the 

safe and proper use of the Generator

A WARNING notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

personal injury or in the worst case death. Do not proceed beyond a WARNING 

notice until the indicated conditions are fully understood or met.
Une note AVERTISSEMENT indique un danger. Elle attire l’attention sur une 

procédure de fonctionnement, un processus ou autre qui, s’il/elle n’est pas 

effectué(e) correctement ou respecté(e), peut entraîner des blessures personnelles 

ou, dans le pire des cas, la mort. Ne continuez pas lorsqu’il y a une note 

AVERTISSEMENT si les conditions indiquées ne sont pas totalement comprises ou 

respectées.

A CAUTION notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

damage to the Generator or the Application. Do not proceed beyond a CAUTION 

notice until the indicated conditions are fully understood or met. 
Une note ATTENTION indique un danger. Elle attire l’attention sur une procédure 

de fonctionnement, un processus ou autre, qui, s’il/elle n’est pas effectué(e) 

correctement ou respecté(e), peut endommager le générateur ou l’application. Ne 

continuez pas lorsqu’il y a une note ATTENTION si les conditions indiquées ne sont 

pas totalement comprises ou respectées.
Caution, risk of electric shock. Ensure power to the Generator has been removed 

before proceeding.
Attention, risque de choc électrique. Assurez-vous que l’alimentation du générateur 

a été coupée avant de continuer.

Safety Notice to Users

These instructions must be read thoroughly and understood before 

installation and operation of your Peak Precision Hydrogen Generator. 

Use of the Generator in a manner not specified by Peak Scientific MAY 

impair the SAFETY provided by the equipment. 

When handling, operating or carrying out any maintenance, personnel 

must employ safe engineering practices and observe all relevant local 

health and safety requirements and regulations. The attention of UK 

users is drawn to the Health and Safety at Work Act 1974, and the 

Institute of Electrical Engineers regulations.

If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired.

WARNING

CAUTION

Page 3

Summary of Contents for Precision SL 100

Page 1: ...Precision Hydrogen SL Installation Guide Rev 3 RSID 3515 EN 10 03 21 Precision SL All Models Installation Guide...

Page 2: ...llation and configuration Please visit www peakscientific com downloads to download the full User Manual for your gas generator Werecommendthatyouread andunderstandthefullusermanual prior to following...

Page 3: ...a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application Do not proceed beyond a...

Page 4: ...29 US Mains Cable C13 5 15 04 1039 US Mains Cable C13 6 15 04 1029 4L Water Bottle 10 9016 x1 x1m Tygon Tubing 05 3131 supplied with all models supplied with automatic and pressure fill models x4 in 2...

Page 5: ...g crate as per the instructions on the box and position on a flat surface in desired area 1 2 Ensure that there is at least 7 5 cm of space to the sides and rear of the generator to allow sufficient a...

Page 6: ...Page 6 To fit the Desiccant Cartridge 3302583 first open the top panel by lifting gently 3 4 Loosen and remove the cap of the desiccant dryer by turning counter clockwise...

Page 7: ...Page 7 Fit the Desiccant Cartridge 3302583 5 6 Replace the cap and hand tighten by turning clockwise...

Page 8: ...Page 8 Fit the DI capsule 3302581 into the recess and rotate 90 clockwise to lock in position 7 8 Close the top panel...

Page 9: ...options following step below 9 For Precision H2 SL equipped with auto water fill or pressurised water fill the Tygon Tubing Barbed Fitting and In Line Filter supplied in the generator fittings kit sho...

Page 10: ...tubing to the Application Connect tubing to the H2 delivery port at the rear of the generator using the 1 8 swagelok compression fitting provided Use new laboratory grade copper or stainless steel tub...

Page 11: ...ppropriate mains cable from the fittings kit and plug the IEC 60320 C13 cable into the mains input at the rear of the generator Please note both 110V and 230V US cables have been supplied ensure corre...

Page 12: ...0 240VAC 50 60Hz single phase power supply CAUTION ensure the correct cable has been selected for your electrical supply 100 240VAC 50 60Hz 100 240VAC 50 60Hz CAUTION UK EU US 110V US 230V 16 Turn the...

Page 13: ...EDs will be solid In the unlikely event that diagnostics are unsuccessful the LEDs will turn orange See Table on Page 15 17 18 Pressing the front button will begin the supply of gas to the application...

Page 14: ...rator and application is stable gas will be supplied by the generator as normal To prevent excess release of hydrogen in the event of a leak between the generator and application the generator s outpu...

Page 15: ...fe of the Generator Ensure that all pipework between generator and equipment is checked for leaks Please familiarise yourself with the full User Manual available at www peakscientific com downloads Th...

Page 16: ...er to the chart below for information regarding the different states LED Indicators Pressurizing Mise sous pression Green Vert At Pressure pression Green Vert See Manual Voir manuel Amber Ambre Contac...

Page 17: ...w peakscientific protected Alternatively you can send the completed form to Peak Scientific by post or email at warranty peakscientific com Product Warranty Registration Contact name Email address Com...

Page 18: ...Page 18...

Page 19: ...Page 19...

Page 20: ...oss every continent around the world This allows us to provide an industry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority T...

Reviews: