background image

LH

RH

   

PREPARE DOOR AND FRAME:
1.   Determine maximum opening angle.

2.   Determine door hand (LH or RH).

3.   Align & attach 

      full size template 
      (see reverse side).
4.   Mark door & frame 
      with center punch.

5.   Remove template before 

      machining door & frame.

5300/5500 DOOR CLOSER INSTRUCTION SHEET

PARALLEL ARM INSTALLATION - PUSH SIDE - DS (NHO) AND DSHO (HO) APPLICATIONS - 105° MAX

INSTRUCTION: 539354
REV. 4             09-05-19

ADJUST SPRING POWER:

1.  Use 4 mm hex key provided to adjust to size on chart.

     Clockwise (CW) turns increase spring power (+).
     Counter-clockwise (CCW) turns decrease spring power (-).

5300/5500 Series closers can be adjusted to meet 

ADA Barrier Free (BF) applications.  Compliance with ADA/BF 

requirements may result with door not fully closing and latching.  
Check with local AHJ.  Closer size may vary due to site conditions.

CW

CCW

(-)

(+)

SPRING 

POWER/SIZE 

ADJUSTING NUT

HEX 
KEY

6

1.   Confirm this sheet is correct for your product and application.

2.   Read the complete instruction sheet before starting installation.
3.   Incorrectly installed or adjusted door closers can cause 

      personal injury or property damage.
4.   To ensure safe operation closers should be examined 
      and serviced, regularly.

TOOLS REQUIRED:

1.   Power drill

2.   10mm box/combo wrench
3.   Phillips screw driver
4.   #7 or 13/64" drill bit and 

      1/4-20 tap (machine screws)

5.   Tap handle
6.   5/32" drill bit (wood screws)
7.   3/8" drill bit (sex nuts)
8.   Center punch

1.   See reverse side of this sheet to machine door & frame.

2.   Dimensions based on 4-1/2" x 4-1/2" full mortise butt hinges

      with 5/8" stop and 1/8" door gap. 

3.   Confirm door & frame are properly reinforced.
4.   Sex nuts required for un-reinforced or composite fire doors.
5.   Do not install closer on the exterior (weather) side of building.

1

2

3

4

5

SLOWER

FASTER

INCREASE

DECREASE

SWEEP SPEED 

DELAYED 

ACTION

BACKCHECK

1.  Use hex key provided.

2.  Adjust SWEEP (closing max.°- 10°).
3.  Adjust LATCH (closing 10°- 0°).
4.  Adjust BACKCHECK resistance (opening 70°- max.°).  
               DO NOT COMPLETELY CLOSE VALVE
5.  Adjust (optional) DELAYED ACTION (closing max.°- 70°);
     Provides additional hesitation for access (ADA/BF) through door.

CONTROL ADJUSTMENTS: 
Closing time of 3-7 seconds is typical.  
More time may be needed for ADA/BF access.

     Clockwise (CW) = SLOWER.
     Counter-clockwise (CCW) = FASTER.
     DO NOT REMOVE VALVES

LATCH SPEED

CLOSING CYCLE

Y

A

L

E

D

E

E

W

S

P

H

C

T

A

L

MAX.°

K

C

A

B

C

E

H

C

K

N

E

P

O

IN

G

OPENING CYCLE

MAX.°

7

8

INSTALL COVER:
1.  Slip cover over closer until  flush with door

     face.
2.  Wide Cover - Orient cover so cutout is at 
     top of closer body. Secure to closer
     with screw on each end.
     Narrow Cover - Cover will snap into slots 
     on closer body. Install dust cap over 
     bottom closer pinion.

NOTE:  Sweep, latch, backcheck, 

and optional delayed action valves 
are all accessible after cover installation.

9

PDQ Manufacturing

2230 Embassy Dr.

Lancaster, PA 17603

833-273-7832

833-2 PDQTECH

www.pdqlocks.com

             

DOOR WIDTH  

                 

APPROX.

       

     

  

SIZE    INTERIOR         EXTERIOR     360° TURNS

  

 BF

 5 LBF ON 36"

     --            -8 (CCW)

  1

   28" [711.2] 

    N/A       

   -6 (CCW)

  2

   32" [812.8]        28" [711.2]

   -4 (CCW)

  3

   36" [914.4]        32" [812.8]

  0 (PRESET)

  4

  42" [1066.8]       36" [914.4]        +5 (CW)

  5

  48" [1219.2]      42" [1066.8]      +9 (CW)

  6

  54" [1371.6]      48" [1219.2]    +12 (CW)

  

INSTALL CLOSER AND ARM:
1.  Attach closer body to door. Sweep & latch    

     valves point away from hinges.
2.  Install bumper stop into DS bracket.
     Bracket is stamped: 
       "L"(left hand) and "R"(right hand).   

3.  Insert filler plug into other hole.
4.  Install DS bracket and spacer block

     to frame.

45°

R

L

S

SPINDLE

ARM

  

4.  Close door & rotate closer 
     spindle 45° toward hinge / pivot.
5.  Install arm parallel to door face, 
     pointing away from hinge.
6.  Secure arm to closer spindle.

RH DOOR SHOWN

53

00

/5

50

0 D

OO

R C

LO

SE

R M

OD

EL

S I

NS

TR

UC

TIO

N S

HE

ET

TE

MP

LA

TE

: 5

39

35

4,

RE

V. 

0  

   

   

01

-1

9-1

7

CL

OS

ER

 B

OD

Y (

LE

FT

 H

AN

D D

OO

R)

CLOSER BODY (RIGHT HAND DOOR)

THIS SIDE UP

FOR RH DOOR

 B

RA

CK

ET

 

(L

H D

OO

R)

 BRACKET

 

(RH DOOR)

TH

IS

 S

ID

E U

P

FO

R L

H D

OO

R

PA

RA

LL

EL

 A

RM

 IN

ST

AL

LA

TIO

N  

- P

US

H S

ID

E -

   

DS

 A

ND

 D

SH

O A

PP

LIC

AT

IO

NS

OPTIONAL HOLD OPEN:

1.  DSHO arm has an optional

     thumb turn "T" handle.

2.  A 1/4 rotation of "T" engages 

     or disengages hold open.

3.  Door can also be 

     manually pulled 
     in and out of hold open 
     without rotating the "T" handle.
4.  Greasing detent ball is recommended 
     to prevent wear.

HOLD 

OPEN

"T" HANDLE

CLOSER 

BODY

DS 

BRACKET

SPACER

BLOCK

PINION /

SPINDLE

HINGE

BUMPER

STOP

FILLER 

PLUG

LH

RH