16
Manual Measurement Mode:
The device is per default in smart measurement mode. Press the
“
AUTO/FUNC
” button to switch to the manual mode and select a
measurement function from left to right by pressing the button
again.
AC/DC Voltage “V" Measurement
1. Press the
button to turn on the device. Insert the red probe
into the
input socket and the black probe into the
“COM” input socket. Let the probe’s tips touch one another, to
check whether they are correctly connected. The indicator light
should turn green and the buzzer sound.
2. Press the “
AUTO/FUNC
” button and choose the function.
Press the “
SEL
” button to switch between AC or DC voltage.
3. Connect the probes’ tips (red probe is the positive pole, black
probe is the negative pole) in parallel to the measuring circuit,
measure the voltage.
4. The measurement result is displayed on the screen.
Summary of Contents for PCW03A
Page 1: ...1 User Manual PCW03A Digital Multimeter...
Page 2: ...2 English 3 Deutsch 49 Fran ais 95 Portugu s 141 187 Italiano 233 Espa ol 279...
Page 188: ...188...
Page 189: ...189...
Page 190: ...190 IEC61010 1 IEC61010 1 CAT III 1000V CAT IV 600V 2...
Page 191: ...191 30V AC True RMS 42V AC peak 60V DC...
Page 192: ...192 LED...
Page 193: ...193 AC DC AC DC CAT II...
Page 194: ...194 CAT III CAT IV 1 NCV 2 3 4 5 6 LCD 7 8 9 10 V LIVE 11 COM 12 mA 600mA 13 10A...
Page 195: ...195 2 AUTO FUNC SEL 2 RANGE mA REL HOLD True RMS True RMS...
Page 196: ...196 Max Min MAX MIN NCV Live 2 Max Min REL HOLD 2 NCV 15 APO...
Page 197: ...197 LED 5...
Page 198: ...198 AC DC 0 5V AC 0 8V DC 1 2 COM 3 4 5 50 6...
Page 199: ...199 1000V DC 750V AC OL...
Page 200: ...200 AUTO FUNC AC DC V 1 COM 2 AUTO FUNC SEL 3 4...
Page 201: ...201 DC 1000V AC 750V OL...
Page 202: ...202 1 COM 2 AUTO FUNC 3 4 5 1MW OL...
Page 203: ...203...
Page 204: ...204 1 COM 2 AUTO FUNC 3 4 50W LED OL...
Page 205: ...205...
Page 206: ...206 1 COM 2 AUTO FUNC 3 4 5 OL...
Page 207: ...207...
Page 208: ...208 1 COM 2 AUTO FUNC 3 4...
Page 209: ...209 AC DC mV 1 COM 2 AUTO FUNC SEL 3 COM 4 5...
Page 210: ...210 DC AC 999 9mV OL...
Page 211: ...211 1 COM 2 AUTO FUNC 3 4...
Page 212: ...212...
Page 213: ...213 1 AUTO FUNC 2 COM 3 4 C F 1 18 28 C 30 2...
Page 214: ...214...
Page 215: ...215 NCV 1 AUTO FUNC NCV LIVE NCV 2 NCV 3 L 4 H...
Page 216: ...216 DC 1000V AC 750V NCV...
Page 217: ...217 Live 1 AUTO FUNC NCV LIVE NCV SEL LIVE LIVE 2 3 L 4 H...
Page 218: ...218 DC 1000V AC 750V LIVE...
Page 219: ...219 AC DC mA 1 AUTO FUNC mA SEL AC DC 2 mA COM 3 4...
Page 220: ...220 600 mA 250V OL...
Page 221: ...221 AC DC A 1 AUTO FUNC 10A SEL AC DC 2 10A COM 3 4...
Page 222: ...222 10 250V OL 5 10 10...
Page 228: ...228 1 40 0 5 0 3 0 400 1 0 2 400 1000 2 0 1 40 32 5 0 6 32 52 1 0 4 752 1832 2 0 1 C 1 F...
Page 229: ...229 1 2 3 4...
Page 230: ...230 1 2 3 mA F600mA 250V 6 32mm 10A F10A 250V 6 32mm 4...
Page 231: ...231 2021...
Page 325: ...325...