PCP BP9000 Instruction Manual Download Page 7

07

PCP Mobile Power Station BP9000

Instruction Manual

Control Unit

1.   Handle

2.   3 AC output sockets (110V/60Hz or 230V/50Hz)

3.   Socket cover

4.   Main switch (I = On, O = Off, II = USB)

5.   LED Battery indicator (displays battery voltage)

6.   LED Power indicator 

7.   LED Status indicator

8.   3 USB sockets

9.   USB socket cover

10.   LED USB indicator

11.   4 Locks

12.   Fan (air inlet)

13.   Fuse

14.   Fan (air outlet)

15.   Mode selection (normal or flash mode)

16.   Plugs to connect battery with control unit

Battery Unit

17.   Charging socket

18.   Charging socket cover

19.   Input socket for external battery (Anode +)

20.   Input socket for external battery (Cathode -)

21.   Built-in battery output

22.   External power output 

Charger

23.   Charging indicator (Rear Side)

24.   AC input socket

25.   Charging connecting cable

26.   Fuse

27.   AC power cable

External power cable 

(optional accessory available in specialized electronics stores)

28. Anode output cable +

29. Cathode output cable -

III. Product description

1. Description of Parts

D

GB

Summary of Contents for BP9000

Page 1: ...in Berührung kommt waschen Sie diese umgehend mit Wasser und Seife ab Bei Berührung mit dem Auge waschen Sie das Auge unter fließendem kaltem Wasser aus und kontaktieren Sie unverzüglich einen Arzt Platzieren Sie keine Werkzeuge aus Metall auf der mobilen Energiestation um Kurzschlüsse zu vermeiden Platzieren Sie keinen Schmuck aus Metall oder ähnliche Gegenstände um die Energiestation herum um Be...

Page 2: ...rschlüsse 12 Eingang Lüftung 13 Sicherung 14 Ausgang Lüftung 15 Modus Auswahl Normal oder Blitz Modus 16 Steckverbindung Akku und Kontrolleinheit Akkueinheit 17 Anschlussbuchse Ladekabel 18 Abdeckung für Anschlussbuchse 19 Anschlussbuchse für externe Batterie Anode 20 Anschlussbuchse für externe Batterie Kathode 21 Ausgang eingebauter Akku 22 Ausgang externer Akku Ladegerät 23 Ladeanzeige Rückseit...

Page 3: ...Wechselstromausgänge sind universell für jedes Land einsetzbar kein Adapter notwendig Standardausgabe 230V 50Hz oder 110V 60Hz IV Gebrauchsanleitung 1 Befestigen und Lösen des Akkus LED Akkuspannung Rot blinkend 10 7 oder 15 4 V Rot 10 7 11 2 V Orange 11 2 12 3 V Grün 12 3 14 6 V Orange blinkend 14 6 15 4 V Wenn die Akkuspannung zurückgeht ändert sich im geladenen Zustand die Farbe der LED Je höhe...

Page 4: ...tion 1 Sekunde bis 800Ws keine Änderung 1 Sekunde über 800Ws Verlängert sich jedoch nicht mehr als 5 Sekunden 2 3 Sekunden bis 2400Ws keine Änderung 2 3 Sekunden über 2400Ws Verlängert sich jedoch nicht mehr als 5 Sekunden 3 Sekunden bis 3000Ws keine Änderung 3 Sekunden über 3000Ws Verlängert sich jedoch nicht mehr als 5 Sekunden Hinweis Bei leerem Akku dauert ein kompletter Ladevorgang etwa 3 Stu...

Page 5: ...mverbrauch bei Nicht Gebrauch Normaler Modus 0 25A Flash Modus 0 9A Klirrfaktor 3 Umwandlungsgrad 91 Signal bei niedrigem Energiestand Ja Abschaltung bei niedrigem Energiestand Ja Lagertemperatur 30 C 70 C Betriebstemperatur 10 C 45 C Akku Typ LiFePO4 Akku Kapazität 12Ah 12 8V Ladedauer ca 3 Stunden Sicherung 3x 30A Abmessungen 267 x 206 x 292 mm Gewicht ca 6 8 kg WEEE Hinweis Die WEEE Waste Elect...

Page 6: ...tery acid come into contact with skin or clothes rinse it with soap and water immediately Should battery acid come into contact with eyes rinse the eyes with cold water and get medical attention immediately To avoid short circuit do not place any metal tool on the battery unit Do not place any jewellery or any other metal objects around the battery unit to avoid any damages caused by high temperat...

Page 7: ... Mode selection normal or flash mode 16 Plugs to connect battery with control unit Battery Unit 17 Charging socket 18 Charging socket cover 19 Input socket for external battery Anode 20 Input socket for external battery Cathode 21 Built in battery output 22 External power output Charger 23 Charging indicator Rear Side 24 AC input socket 25 Charging connecting cable 26 Fuse 27 AC power cable Extern...

Page 8: ...niversally applicable for each country no adapter needed Standard voltage 230V 50Hz or 110V 60Hz IV Operation instruction 1 Installation and detachment of battery unit LED Battery voltage Red blinking 10 7 oder 15 4 V Red 10 7 11 2 V Orange 11 2 12 3 V Green 12 3 14 6 V Orange blinking 14 6 15 4 V In loaded operation the LED light changes when battery voltage goes down The higher the load power is...

Page 9: ...ery life please fully charge power station 1 each time after using the power station 2 when the power station has not been used for about 100 days 2 Connect your device with one of the 3 AC output sockets 2 3 Turn main switch 4 to I On 4 Turn mode selection 15 to required mode Flash or Normal 5 Turn on the connected device Now the device draws power from power station 2 Normal Mode For electric de...

Page 10: ...current Note Ensure that plugs of control unit 16 and the external power output 22 of battery unit are locked properly When using external battery the built in battery of power station will not be charged VIII Maintenance and warranty Wipe the mobile power station BP9000 with a dry cloth to clean it from dust and dirt Any damages caused by improper use are not covered by the warranty Subject to ch...