20
L510010-11
STOPPING ENGINE
When returning to the dock, or whenever stopping the
engine, bring the throttle back to the idle position and the
transmission to Neutral. After the engine reaches idle
speed, turn the ignition key to the OFF position.
Before stopping the engine after extended high speed
operation, allow the engine to idle at 1200 RPM for 3 to 5
minutes to allow the engine to cool down before shutting
off the ignition.
After stopping the engine, complete the following:
1. Turn the battery switch OFF, if equipped.
2. Close the fuel valve.
3. Close the seacock.
4. Flush the cooling system if in a salt water area.
OPERATING INSTRUCTIONS - 5
FREEZING TEMPERATURE OPERATION
If the possibility of freezing exists, the cooling system
must be protected after the engine is shut off to prevent
freeze damage to the engine. Refer to OUT-OF-
SEASON STORAGE for draining instructions.
OPERATION IN HIGH DEBRIS AREAS
If the boat is to be operated in high debris areas, a sea
strainer should be installed in the water inlet hose to
prevent debris from entering the cooling system. The
strainer used must be of suf
fi
cient size to allow an
adequate supply of water for cooling the engine. A
minimum of 30 gallons per minute (114 liters per minute)
fl
ow rate is required.
Summary of Contents for 2008 Catanium CES 6.0L ZR-409
Page 1: ...OWNER S OPERATION and MAINTENANCE MANUAL A Division of...
Page 2: ...This Page Was Intentionally Left Blank...
Page 12: ...8 L510010 11 This Page Was Intentionally Left Blank INTRODUCTION 1...
Page 89: ...85 L510010 11 NOTES 20...
Page 92: ...This Page Was Intentionally Left Blank...
Page 93: ...Pleasurecraft Engine Group 1737 Highway 76 East Little Mountain SC 29075...