background image

Trademarks 

Copyright @2000 PLANEX COMMUNICATIONS INC.

Contents subject to change without prior notice.

Pci is a registered trademark of PLANEX COMMUNICATIONS INC. 

All other trademarks belong to their respective proprietors. 

Copyright Statement 

No part of this publication may be reproduced in any form or by any means

or used to make any derivative such as translation, transformation, or

adaptation without permission from PLANEX COMUNICATIONS INC.

CE Mark Warning 

This is a Class A product.  In a domestic environment, this product may

cause radio interference in which case the user may be required to take

adequate measures. 

VCCI

Voluntary Control Council for Interference (VCCI-A) Compliance

(Insert the Japanese statement on VCCI)

Safety Instruction

Unplug this product from the wall outlet before cleaning.  Do not use

liquid or cleaners or aerosol cleaners.  Use a damp cloth for cleaning.

Do not use extra/optional attachments unless their use is recommended by

the product manufacturer.  Doing so may cause hazards.

Do not use this product near water.

Do not place this product on an unstable cart, stand or table as the product

may fall, harming people as well as the appliance itself.  When mounting

the product to a wall or shelf, be sure to follow the manufacturer’s  

instructions.You may only use a mounting kit approved

by the manufacturer.

Slots and openings on the back or bottom of the cabinet are provided for

ventilation to insure reliable operation of the product.  The openings must

not be blocked as it may cause overheating.  Do not place this product on a

bed, sofa, rug or any other similar surface.  The product should never be

placed near or over a radiator or heat register.  Similarly, this product must

not be placed in a built-in installation such as a bookcase unless proper

ventilation is provided.

This product should be used only with the appropriate power source

indicated on the marking label.  If you are not sure which type of power is

supplied at your home, please consult your dealer or an electric power

company.

For added protection, turn off and unplug the product from the wall outlet

whenever it is left unattended or unused for a long period of time.  This

will prevent damage to the product due to power surges.

Do not overload wall outlets or extension cords as this may result in a

short circuit or fire.  

Do not attempt to insert any object via openings on the cabinet as it may

cause a serious electric shock or fire.  Never spill a liquid of any kind on

the product. 

Summary of Contents for FX-05SC

Page 1: ...da Takahashi Bldg 1 7 Kanda Sudacho Chiyoda Ku Tokyo 101 0041 Japan Tel 81 3 3256 9091 Fax 81 3 3256 9207 TAIWAN http www planex com tw E mail info planex planex com tw 11F No 190 Chung Cheng Rd Hsin...

Page 2: ......

Page 3: ...ople as well as the appliance itself When mounting the product to a wall or shelf be sure to follow the manufacturer s instructions You may only use a mounting kit approved by the manufacturer Slots a...

Page 4: ...change in performance indicating a need of repair When replacement parts are required be sure to obtain parts specified by the manufacturer Unauthorized substitutions may result in fire electric shoc...

Page 5: ...onmental Requirements Installing the Switching Hub Connecting the Power Cable to the Switch Connecting Computers to FX 05SC 10 Cascading to an Additional Hub or a switch 1 1 2 3 4 5 1 1 2 3 4 5 Append...

Page 6: ...hen combined with a network adapter with Flow Control support ex FNW 9802 T the switch can perform Flow Control in 200M full duplex Provides five RJ 45 STP ports for 100BASE TX 10BASE T connection Com...

Page 7: ...s detected on the port 1 4 Parts Terminology 1 1 Front Panel LED indicators for monitoring the status of each port and the network Provides one uplink port for cascading to another hub Fan less quiet...

Page 8: ...to include this information in your user registration form This number is also required for all technical support services 1 3 Bottom View Rear Panel Port 1 5 RJ 45 ports for 100BASE TX 10BASE T conne...

Page 9: ...nt to one of the ports immediately after its destination address is discerned Since packets themselves are not inspected some error packets may leave the switch among normal packets In contrast Store...

Page 10: ...any dirt by a vacuum cleaner etc Always place the product on a level surface ex desktop Avoid placement on an unstable or uneven surface 8 FX 05SC Chapter 2 Installation 2 1 Environmental Requirement...

Page 11: ...ch 2 1 Connecting by RJ 45 Ports 1 Attach the supplied AC power adapter to the power jack on the rear panel 2 Connect the power adapter to a wall outlet 3 Verify that the Power LED on the front panel...

Page 12: ...one end of the cable to the uplink port on the FX 05SC 3 Connect the other end of the cable to any of the 100BASE TX 10BASE T RJ 45 ports on the other device The Link Act LED illuminates if a valid 10...

Page 13: ...reseller for assistance 2 Perform the following tests Please check whether the RJ 45 cable is functional Replace with another working cable and see whether the condition can be improved Be sure to us...

Page 14: ...or Full Duplex mode There is a non standardized technology called Auto sensing Unlike Auto negotiation Auto sensing detects only the 10BASE T 100BASE TX speed modes CANNOT recognize the duplex modes...

Page 15: ...plied to 10BASE T cascading Please see the table below and Figure C 1 and C 2 for more information on cascading limitations for 10BASE T 100BASE TX networks A switching hub can be inserted in the netw...

Page 16: ...21 C 3 The limitation of cascading switching hub FX 05SC 20 FX 05SC C 1 The limitation of cascading 100BASE T C 2 The limitation of cascading 10BASE T...

Page 17: ...ns Supports filtering forwarding and address learning of packets Filtering Forwarding Rate 148 800pps Max Switching Scheme Store and Forward Address Table 1 000 entries Packet Buffer 128KB Flow Contro...

Page 18: ...24 FX 05SC...