TDS-100H Handhold Ultrasonic Flowmeter Ver.8.08 - 10 -
The major reason why the menu windows are arranged in this way is that the software
programmer hopes that the menu window arrangement for this version has the most/high
????
compatibility with the previous versions of the flow meter software. This will make it easier
for the former version users with this flow meter series.
§2.6 Steps to Configure the Parameters
The following parameters need to be configured for a proper measurement:
(1)
Pipe outer diameter
(2)
Pipe wall thickness
(3)
Pipe materials (for non-standard pipe materials*, the sound speed for the material must
be configured too)
*Standard pipe materials and standard liquids refer to those with the sound parameters
that have already been programmed into software of the flow meter, therefore there is
no need to configure them
(4)
Liner material and its sound speed and thickness, if there is any liner.
(5)
Liquid type (for non-standard liquids, the sound speed of the liquid is also needed)
(6)
Transducer type adapted to the flow meter. Generally the Standard M1 or the Frame
M-sized transducers will be the selected option.
(7)
Transducer mounting methods (the V-method or Z-method is the common option)
(8)
Check up the Space displayed on M25 and install the transducers accordingly.
For standard pipe materials and standard liquids, the following detailed step-by-step setup is
recommended.
(1) Press keys MENU 1 1 to enter M11 window to input the digits for the pipe outer
diameter, and then press ENT key.
(2) Press key
▼
/-
to enter M12 window to input the digits for the pipe outer diameter and
then press ENT key.
(3) Press key
▼
/-
to enter M14 window, and press ENT key to enter the option
selection mode. Use keys
▲
/+
and
▼
/-
to scroll up and down to the intended pipe
material, and then press ENT key.
(4) Press key
▼
/-
to enter M16 window, press ENT key to enter the option selection
mode, use keys
▲
/+
and
▼
/-
to scroll up and down to the liner material, and then
press ENT key. Select “No Liner”, if there is no liner.
(5) Press key
▼
/-
to enter M20 window, press ENT key to enter the option selection
mode, use keys
▲
/+
and
▼
/-
to scroll up and down to the proper liquid, and then
press ENT key.
(6) Press key
▼
/-
to enter M23 window, press ENT key to enter the option selection
mode, use keys
▲
/+
and
▼
/-
to scroll up and down to the proper transducer type, and
then press ENT key.
(7) Press key
▼
/-
to enter M24 window, press ENT key to enter the option selection
mode, use keys
▲
/+
and
▼
/-
to scroll up and down to the proper transducer mounting
method, and then press ENT key.
(8) Press key
▼
/-
to enter M24 window to install the transducers on the pipe, and then
press ENT key to go to M01 for the results.