![PCE Instruments PCE-VT 2700 User Manual Download Page 8](http://html1.mh-extra.com/html/pce-instruments/pce-vt-2700/pce-vt-2700_user-manual_1516157008.webp)
English
EN - 8
English
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only
be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or
injuries caused by non-observance of the manual.
- The device may only be used in the approved temperature range.
- The case should only be opened by qualified personnel of PCE Instruments.
- The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a
table).
- You should not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner.
- The meter contains magentic components. Therefore, keep it away from people with cardiac pacemakers etc.
This manual is published by PCE Instruments without any guarantee.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments.
2 Specifications
Measurement range acceleration
0.0 ... 399.9 m/s² (Peak) / 0.0 ... 1311 ft/s² (Peak)
Measurement range velocity
0.00 ... 399.9 mm/s (RMS) / 0.00 ... 15.75 inch/s (RMS)
Measurement range displacement
0.000 ... 3.999 mm (Pk-Pk) / 0.000 ... 158.0 mil (Pk-Pk)
Measurement range revolutions
50 … 99.900 rpm (reading must be multiplied by 10)
Resolution
0.1 m/s²; 0.1 mm/s; 1 µm, 1 rpm
Accuracy
± 5% of r 2 digits
Frequency range acceleration
10 Hz … 1 kHz (in 1 kHz mode) / 10 Hz … 10 kHz (in 10 kHz
mode)
Frequency range velocity
10 Hz … 1 kHz
Frequency range displacement
10 Hz … 1 kHz
Display
4-digit LC display, value last measured is displayed
Units
selectable: metric or imperial
Interface
RS-232
Power supply
3 x 1.5 V AAA batteries / LR03
battery life up to 5 hours at continuous operation
Auto Power Off
5 minutes after last keystroke
Low Bat symbol
<2.1 V
Operating conditions
-5 ... +55 °C; 0...95 % RH; non-condensing
Dimensions
150 x 77 x 40 mm
Weight
225 g (with batteries)