Making Measurement 

 

Introduction 

 

Chapter 3 explains how to make measurements.   
You could turn the Meter off by turning to 

OFF

 position or set up the sleep mode from 1-30 minutes.  

Please must ensure the Meter is not under sleep mode if you turn the Meter on but without display. 
To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery 
as soon as the battery indicator “ ” appears. 
 

A. Scope 

Mode 

z

  The LCD top right part display: RUN, HLD, REV  

z

  The LCD top right corner has battery icon   to indicate when the battery is lower than 5V. 

z

  Under scope mode, both reading and waveform will be displayed. 

 

i. 

Setting up Sleep Mode, Contrast, Beep 

Based on the working environment to set up sleep mode, contrast, beep 
Press 

Set

 button to set the auto power off, display backlight, contrast and beep 

Auto off

     

Bk Light

    

Contrast

      

Beep

  

F1          

F2 

     F3   

 F4 

 
F1: Set auto power off time 

Auto off

    

 

15

 

     

ENTER

  

F1 

F2   F3         

F4 

The time level is from OFF, 1 to 30 minutes.  Press F4 to confirm, save and return. Press functional 
button to exit and the setting remains unchanged. 
 

 

F2:  Set the Display Backlight  

BK Light

     

 

15

 

      

ENTER

  

F1     

F2     F3         F4 

The brightness level from 0 to 31.  Press F4 to confirm, save and return.  Press functional buttons to exit, 
the setting is kept, but will not save.  The setting will be lost after power off. 
 

 

F3:  Set the LCD contrast 

Contrast

      

 

15

 

     

ENTER

  

F1     

 F2     F3         F4 

The contrast level from 0 to 31.  Press F4 to confirm, save and return.  Press functional buttons to exit, 
the setting is kept, but will not save.  The setting will be lost after power off. 
 
F4:  Set the beeps features, it can only be used under resistance, diode and continuity measurement. 

Beep 

     

  ON  

      

  OFF 

    

ENTER 

F1     

F2          F3         F4 

F2 to turn the beep on 
F3 to turn the beep off 
F4 to confirm , save and return 
Press functional buttons to exit, the setting is kept, but will not save.  The setting will be lost after power 
off. 

 

 

 

Summary of Contents for PCE-UT81B

Page 1: ...echnical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com...

Page 2: ...ation 4 International Electrical Symbols 5 Using the Testing Tool 5 Reading the Screen 5 The Meter Structure 6 Functional Buttons 7 Making Measurement 8 Introduction 8 A Scope Mode 8 B Digital Multime...

Page 3: ...rate sampling process can catch up pulse industrial signal It can measure AC DC engine transducer circuit control UPS and industrial equipments It is an ideal tools in professional repairing industrie...

Page 4: ...The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter z When the Meter working at an effe...

Page 5: ...e Screen The screen displays the menu that provides the following choices available Table 2 1 Reading the Screen Display Description Contrast The degree of contrast Auto Off Sleep mode time BK Light D...

Page 6: ...unc 3 Rota 4 COM 5 mA eter Struct re 2 1 shows D Display ctional Butto ary Switch M Input Term A Input Term ture s the Meter s ns minal minals structure Figure 2 1 Meter Structure i info tursdaletec c...

Page 7: ...e P n measuring nvalid when m d capacitanc mode Press uto between wav multimeter mo equency cur button to se pe mode pre d button to e d with the rotar al Buttons al Buttons ttons details ress Range b...

Page 8: ...and beep Auto off Bk Light Contrast Beep F1 F2 F3 F4 F1 Set auto power off time Auto off 15 ENTER F1 F2 F3 F4 The time level is from OFF 1 to 30 minutes Press F4 to confirm save and return Press func...

Page 9: ...ess Auto When the amplitude is set to auto the amplitude indicator will be shown white text in black background When the amplitude is set to manual the amplitude indicator will be shown black text in...

Page 10: ...u need to press HOLD button to continue measurement z If you recall the location has data it will save the current setting and display the data the LCD top left shows REV to indicate recalling mode is...

Page 11: ...d 4 The measured value shows on the display 5 Press MODE button to toggle between Multimeter mode and Scope mode 6 Press F1 to toggle between AC and DC voltage measurement When measuring voltage the c...

Page 12: ...uit before test leads are connected in series to the return circuit to be tested z A Range Measurement To measure AC A or DC A currents set up the Meter as Figure 3 3 and proceed as follows Black Red...

Page 13: ...Press MODE button to toggle between Multimeter mode and Scope mode 6 Press F1 to toggle between AC and DC current measurement z 10A Range Measurement To measure AC 10A or DC 10A currents set up the M...

Page 14: ...measured current is 5A continuous measurement is allowed z When the measured current is between 5A 10A continuous measurement 10 seconds and interval more than 15 minutes z When current measurement ha...

Page 15: ...indicating open circuit without input z When resistance measurement has been completed disconnect the connection between the testing leads and the circuit under test and remove testing leads away from...

Page 16: ...ther open circuit or wrong polarity connection z The unit of diode is volt V displaying the positive connection voltage drop value z When diode testing has been completed disconnect the connection bet...

Page 17: ...t terminals vi Measuring Frequency Duty Cycle Warning To avoid harms to you please do not attempt to input voltage higher than 42V rms To measure frequency and duty cycle connect the Meter as Figure 3...

Page 18: ...10 and proceed as follows Black Red Figure 3 10 Measuring Capacitance 1 Insert the red test lead into the terminal and the black test lead into the COM terminal 2 Set the rotary switch to measurement...

Page 19: ...struction Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration performance test and service information A General Service z Period...

Page 20: ...tment and separate the battery compartment from the case bottom z Remove the three screws from the case bottom and separate the case bottom from the case top z Remove the fuse by gently prying one end...

Page 21: ...Terminal and Grounding Refer to different range input protection voltage Certification Compliances IEC 61010 CAT II 1000V CAT III 600V overvoltage and double insulation standard Fused Protection for...

Page 22: ...USB Optically isolated to ensure safety Tilt Stand Allowing viewing at a convenient position and angle Feature Summary Display 160 x 160 Monochrome Autorange When it is under multimeter mode the Meter...

Page 23: ...um input voltage 1000Vp Voltage Sensitivity 200mV div 500V div 1 2 5 Detailed Accuracy Specifications Accuracy of reading number of least significant digits guarantee for 1 year Operating temperature...

Page 24: ...0A 250V fast type fuse 5 20mm Continuous measurement 10 seconds and interval more than 15 minutes 10A 10mA D AC Current i Under Multimeter mode Range Resolution Accuracy Overload Protection 400 A 0 1...

Page 25: ...5V and 0 8V G Continuity Test Range Resolution Overload Protection Remarks 0 1 250V DC or AC z The buzzer sounds when the test resistance is 10 z The buzzer does not sound when the test resistance is...

Page 26: ...the peak peak difference value is greater than 1 3 div the reading is valid otherwise the Meter displays I Capacitance Range Resolution Accuracy Overload Protection 40nF 10pF Under REL mode 3 10 250V...

Reviews: