background image

 

 

 

©  PCE Instruments 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 4 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 SOULTZ-SOUS-FORETS 

02500 Tobarra (Albacete) 

Deutschland  

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 
 

 

 

United States of America 

United Kingdom 

Italy 

PCE Americas Inc. 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

711 Commerce Way suite 8 

Units 12/13 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Jupiter / Palm Beach 

Ensign Way, Southampton 

55010 LOC. GRAGNANO  

33458 FL  

Hampshire  

CAPANNORI (LUCCA) 

USA 

United Kingdom, SO31 4RF 

Italia 

Tel: +1 (561) 320-9162 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Fax: +1 (561) 320-9176 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/us 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

 
 

 

 

The Netherlands 

Chile 

Hong Kong 

PCE Brookhuis B.V. 

PCE Instruments Chile S.A. 

PCE Instruments HK Ltd. 

Institutenweg 15 

RUT: 76.154.057-2 

Unit J, 21/F., COS Centre 

7521 PH Enschede 

Santos Dumont 738, local 4 

56 Tsun Yip Street 

Nederland 

Comuna de Recoleta, Santiago, Chile 

Kwun Tong 

Telefoon: +31 (0)53 737 01 92 

Tel. : +56 2 24053238 

Kowloon, Hong Kong 

Fax: +31 53 430 36 46 

Fax: +56 2 2873 3777 

Tel: +852-301-84912 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/dutch 

www.pce-instruments.com/chile 

www.pce-instruments.cn 

 
 

 

 

China 

Turkey 

PCE (Beijing) Technology Co.,Ltd 

PCE Teknik Cihazları Ltd.Şti. 

1519 Room, 6 Building 

Halkalı Merkez Mah. 

Men Tou Gou Xin Cheng, 

Pehlivan Sok. No.6/C 

Men Tou Gou District 

34303 Küçükçekmece - 

İstanbul 

102300 Beijing 

Türkiye 

China  

Tel: 0212 471 11 47 

Tel: +86 (10) 8893 9660 

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

www.pce-instruments.cn 

www.pce-instruments.com/turkish 

 
 

 

 

Summary of Contents for PCE-PHM 14

Page 1: ...M 14 pH Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 2...

Page 2: ...s 1 2 Features 2 3 Applications 2 4 Specifications 2 5 Front Panel Description 3 6 Calibration 3 7 Important information on the calibration 5 8 Clear calibration 6 9 Measuring procedure 6 10 Delivery...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...ions Measuring range 0 14 pH Resolution 0 01 pH Accuracy at 23 C 5 C after calibration 0 07 pH at 5 9 pH 0 1 pH at 4 10 pH 0 2 pH at 1 3 9 pH 10 1 13 pH Input impedance 1012 Ohm Sampling rate approx 1...

Page 5: ...BNC socket 6 DC 9 V input socket 7 Positioning aid for adhesive pads 8 Apertures for fixing 6 Calibration Prerequisites for calibration Ideally the electrode will produce 0 mV at pH 7 00 The ideal amb...

Page 6: ...ear The display will show 7 00 pH CAL 5 Press the ENTER key to confirm Calibration procedure pH 4 1 Rinse the electrode in distilled water completely 2 Connect the pH electrode to the meter and immers...

Page 7: ...ill show 7 00 pH CAL 5 Press the Down key until the desired calibration value appears 10 00 pH CAL 6 Press the ENTER key to confirm 7 Important information on the calibration Before and after immersin...

Page 8: ...ss the Down key until the following appears CLr pH CAL 4 Press the ENTER key to confirm When the calibration has been cleared the display will show End 9 Measuring procedure 1 Power on the instrument...

Page 9: ...tive of the European Parliament applies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order...

Page 10: ...583 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english w...