background image

 

          6-Channel Modbus 

Infrared Thermometer PCE-IR 56 

Operator’s Guide

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

    [email protected]

Summary of Contents for PCE-IR 56

Page 1: ...From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info industrial needs com ...

Page 2: ...loves on With an optional MicroSD Card inserted the P C E I R 5 6 SPECIFICATIONS Display 2 83 72 mm resistive touch TFT 320 x 240 pixels backlit Supply Voltage 10 to 30 V DC Maximum Current Draw 100 mA Ambient Temperature Range 0 C to 60 C Relative Humidity Maximum 95 non condensing Configurable Parameters global Temperature units date and time data logging graph channels alarm logging Configurabl...

Page 3: ...Modbus network logging may also be started remotely by the Modbus Master on that network DATA LOGGING SPECIFICATIONS Logging Interval 1 to 86 400 seconds 1 day MicroSD Card Max capacity 32 GB not included Internal Clock Battery 1 x BR 1225 3V not included Variables Logged Target temperature sensing head temperature alarm events File Format csv can be imported to Excel Configurable Parameters Sampl...

Page 4: ...output modules Be sure to check the power supply requirements of each device before applying power Optionally connect the Slave interface to another Modbus network with its own Modbus Master such as a PLC or SCADA system Isolation is provided between the Slave and Master interfaces MICROSD CARD AND BATTERY The MicroSD Card and battery slots are located on the touch screen circuit board Unscrew the...

Page 5: ...5 12 V DC 24 V DC PyroBus sensor PyroMini or FibreMini sensor PyroMiniBus sensor PASSWORD The default password is 1234 The password may be changed via the touch screen interface ...

Page 6: ...ettings R W Bit 0 Log trigger time Bit 1 Log while triggered Bit 2 Log acknowledge time Bit 3 Log reset time 0x0020 1 Remote request Start logging R W Write 1 request start of data logging Read 1 request pending Read 0 no request pending 0x0021 1 Remote request Stop logging R W Write 1 request termination of data logging Read 1 request pending Read 0 no request pending 0x0022 1 Remote request Ackn...

Page 7: ...r Sensor index Address offset 0 0x1000 1 0x1100 2 0x1200 3 0x1300 4 0x1400 5 0x1500 6 0x1600 See sensor manual for further details Notes 1 For further information please refer to http www modbus org specs php 2 Use address 255 to communicate with any connected unit only one sensor connected 3 Use address 0 to broadcast to all connected units no response expected ...