The  P C E - I R   5 6
PCE Instruments infrared  temperature  sensors. 

The P C E - I R  5 6  functions as the Modbus Master on an RS485 network of up to 6 temperature sensors, 
and can itself be connected as a slave device to another RS485 network via a second, isolated 
Modbus interface. This allows multiple P C E - I R  5 6  units to be multi-dropped to create a large network 
of sensors and displays.
Optional  alarm  relay  modules  allow  the  P C E - I R  5 6   to  be  connected  to  alarm  equipment  such  as 
sounders and beacons, and optional analogue output modules allow it to be connected to non-
Modbus instrumentation.

modules  are  adjustable  via  the  P C E - I R  5 6   built-in  resistive  touch  screen  interface,  which  can  be 
operated even with gloves on.
With an optional MicroSD Card inserted, the P C E - I R  5 6

SPECIFICATIONS

Display

 

2.83” (72 mm) resistive touch TFT,  

 

 

 

320 x 240 pixels, backlit

Supply Voltage 

10 to 30 V DC

Maximum Current Draw 

100 mA

Ambient Temperature Range 

0°C to 60°C

Relative Humidity 

Maximum 95%, non-condensing

Configurable Parameters (global) 

Temperature units, date and time, data logging,    

 

graph channels, alarm logging

Configurable Parameters (per channel) 

Signal processing, emissivity setting, reflected energy  

 

compensation, alarms, Modbus address

Alarm Configuration

 

12 alarms (2 per sensor) with adjustable level,  

 

 

individually configurable as HI or LO.

Temperature Units 

°C or °F selectable

Temperature Resolution 

0.1° below 1000°; 1° above 1000°

Signal Processing

 

Average, peak hold, valley hold, minimum, maximum

Display Sample Period

 

120 ms per device (720 ms in total for 6 devices)

 

 
 
 

 

 

 

 

 

 

   

 

 

MECHANICAL

Dimensions

 

98(w) x 64(h) x 36(d) mm excluding cable glands

Weight

 

280 g

Summary of Contents for PCE-IR 56

Page 1: ...From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info industrial needs com ...

Page 2: ...loves on With an optional MicroSD Card inserted the P C E I R 5 6 SPECIFICATIONS Display 2 83 72 mm resistive touch TFT 320 x 240 pixels backlit Supply Voltage 10 to 30 V DC Maximum Current Draw 100 mA Ambient Temperature Range 0 C to 60 C Relative Humidity Maximum 95 non condensing Configurable Parameters global Temperature units date and time data logging graph channels alarm logging Configurabl...

Page 3: ...Modbus network logging may also be started remotely by the Modbus Master on that network DATA LOGGING SPECIFICATIONS Logging Interval 1 to 86 400 seconds 1 day MicroSD Card Max capacity 32 GB not included Internal Clock Battery 1 x BR 1225 3V not included Variables Logged Target temperature sensing head temperature alarm events File Format csv can be imported to Excel Configurable Parameters Sampl...

Page 4: ...output modules Be sure to check the power supply requirements of each device before applying power Optionally connect the Slave interface to another Modbus network with its own Modbus Master such as a PLC or SCADA system Isolation is provided between the Slave and Master interfaces MICROSD CARD AND BATTERY The MicroSD Card and battery slots are located on the touch screen circuit board Unscrew the...

Page 5: ...5 12 V DC 24 V DC PyroBus sensor PyroMini or FibreMini sensor PyroMiniBus sensor PASSWORD The default password is 1234 The password may be changed via the touch screen interface ...

Page 6: ...ettings R W Bit 0 Log trigger time Bit 1 Log while triggered Bit 2 Log acknowledge time Bit 3 Log reset time 0x0020 1 Remote request Start logging R W Write 1 request start of data logging Read 1 request pending Read 0 no request pending 0x0021 1 Remote request Stop logging R W Write 1 request termination of data logging Read 1 request pending Read 0 no request pending 0x0022 1 Remote request Ackn...

Page 7: ...r Sensor index Address offset 0 0x1000 1 0x1100 2 0x1200 3 0x1300 4 0x1400 5 0x1500 6 0x1600 See sensor manual for further details Notes 1 For further information please refer to http www modbus org specs php 2 Use address 255 to communicate with any connected unit only one sensor connected 3 Use address 0 to broadcast to all connected units no response expected ...

Reviews: