Specifications
Measuring range
0 ... 200 N
Calibration
0.1 N
Pressure calibration
1 Mpa
Load cell
integrated load cell with M6 connection
Measuring range
1 ... 100 % of the full scale
Measurement accuracy
±0.5 %
Units
n, kg, lb
Display
LCD
Operating temperature
+10 ... +30 °C / +50 ... +86 °F
Relative humidity
15 ... 80 %
Working conditions
the device must not be located near sources of vibration or
corrosive substances
Weight
1 kg / 2.2 lb
3
Important information before use
•
Before the impact test, wear mask and gloves; avoiding personal injury in case of object
splash.
•
Do not use damaged or bent fixture; avoiding personal injury in case of fixture fall or break.
•
If “Err-1” appears on the LCD, it indicates that the test load the sensor measures is 110 %
larger than the rated load. Decrease the load immediately. Make sure the load applied is
smaller than 105 % the rated load after the force gauge is restarted.
•
Make sure the force gauge is not overloaded. Overload, excessive impact force and forces
other than pull force and push force may damage the sensor.
•
Do not use sharp tools to press buttons.
•
Keep the force gauge away from water, oil, and other liquids. Put it in a cool, dry, and
vibration-free place.
•
Use the charger delivered with the force gauge for charging; otherwise, circuit failure or even
fire may be caused.
•
Follow this document to wire ports; otherwise, circuit failure or even PC fault may be caused.
•
Make sure the AC charger is securely inserted into a socket if the product needs to be
charged. Looseness may cause short circuit, resulting in electric shock or fire.
•
Remove the power adaptor after charging to avoid accidents.
•
Do not touch the power adaptor with wet hands; otherwise, electric shock may occur.
•
This product is for measuring pull and push forces only. Do not bend or twist the test head.
See the following figure for correct operation method.