Hold function 

Whenever you press the Hold Button, the current reading will freeze and a "HOLD" symbol will 

appear on the display. Press the Hold Button again to unfreeze the value and proceed with your 

ongoing measurement. 

MAX/MIN data recording 

Recording can be started by pressing the MIN/MAX Button. “REC” will appear in the display. Only 

the lowest and the highest value will be saved when using this function. All other values will be 

dropped. Press the MIN/MAX Button to view the  saved values. Press the Hold Button to start 

recording again. To get back to normal measurement mode, press and hold the MAX/MIN Button 

for three seconds. 

Auto Power Off  

In order to prolong the battery life, the instrument has an "Auto Power Off" function. The meter 

will switch off automatically if no buttons are pressed for around 10 minutes. When data are 

recorded or a value has been held, this function will be disabled. 

10  Battery level indicator 

When the LCD display shows the 

 symbol, it is necessary to replace the 9 V block battery. 

Measurement  may  still  be  made  for  several  hours  after  the  low  battery  indicator  appears. 

However, faulty measurements can occur then. 

 

To change the battery, open the battery compartment cover on the rear side of the meter. To 

loosen the screw, you will need a screwdriver. Remove the old battery and replace it by a new 

one. Observe correct polarity and re-install the battery compartment cover. 

 

Summary of Contents for PCE-EM 888

Page 1: ...88 Lux Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 10...

Page 2: ...4 6 1 Air flow measurement and temperature 5 6 2 Volume flow measurement 5 6 3 Barometric pressure measurement abs pressure 5 6 4 K type thermocouple 5 6 5 Light measurement 5 6 6 Humidity and ambien...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...er 2 1 Delivery contents 1 x PCE EM 888 hygrometer 1 x Type K thermocouple sensor TF 500 1 x 9V battery 1 x User manual 3 Specifications Wind speed Measuring range 80 5910 ft min 0 4 30 m s 1 4 108 km...

Page 5: ...hPa 1 hPa 0 1 mmHg 0 01 inHg Accuracy 1 5 hPa 2 hPa 1 2 mmHg 0 05 inHg General specifications Display 8 mm 0 32 LCD Measurement functions Air speed velocity Volumetric air flow Relative humidity Air...

Page 6: ...AX Min recording has been started REC icon in the display you will not be able to turn off the instrument 6 Measuring Functions The meter has these 7 functions Display indication Measuring function An...

Page 7: ...ressure To change the unit for the air pressure measurement press the Unit Zero Button You can select HPA inHP or mmHP 6 4 K type thermocouple First plug a K type thermocouple into the socket of the d...

Page 8: ...old the MAX MIN Button for three seconds 9 Auto Power Off In order to prolong the battery life the instrument has an Auto Power Off function The meter will switch off automatically if no buttons are p...

Page 9: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 10: ...583 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english w...

Reviews: