Weight 

6.2 oz. (175g) including battery 

Dimensions 

164 x 65 x 32mm    (6.5 x 2.6 x 1.3”) (HXWXD) 

Jaw opening 

18mm  (0.7”) 

Standards 

IEC61010 Category II 600V,   

z

 

Range Specifications 

Function 

Range 

Resolution 

Accuracy (of reading)

 

 

DC Current 

200A 

100mA 

± (2.8% + 8 digits)   

AC Current (50/60Hz) 

200A 

100mA 

±(3.0% + 8 digits) 

Frequency 

(Auto-Ranging) 

40-51Hz 

0.01Hz 

±(1.2% + 5 digits) 

Input Sensitivity: 5A AC RMS min. 

51-510Hz 0.1Hz 

0.51-1kHz 0.001kHz 

Non-Contact AC Voltage 

100VAC to 600VAC 50/60Hz 

 

Meter Description 

1, Current sense jaw 

2. Flashlight button 

3. Rotary function switch 

4. Data HOLD and Backlight key 

5. LCD display 

6. Clamp trigger 

7. One-touch DCA ZERO key 

8. Non-contact AC voltage indicator light 

9.

 

Non-contact AC voltage detector probe tip 

 

Safety Information 

!

  Caution!    Refer to the explanation in this Manual 

 

Double Insulation 

This meter has been designed to be safe in use, but the operator must use caution in its operation. The 

rules listed below should be carefully followed for safe operation. 

1. 

NEVER

 apply voltage or current to the meter that exceeds the specified maximum: 

2. 

USE EXTREME CAUTION

 when working with voltages greater than 25VAC rms. These voltages are 

considerd a shock hazard. 

3. 

  NEVER

 operate the meter unless the back cover and the battery/fuse door are in place and fastened 

securely 

Input Limits 

CC