Maintenance and Control
Inspection prior to each operation with the device
An inspection of the device must be performed prior to the initiation of the operation. The operator must
check the following aspects:
- There should be no visible deformation or damages, e.g. fractures.
- All compartments and attaching parts should be complete and in a flawless condition (e.g. safety splints
etc.)
- The entire system must be installed neatly so that there is no potential hazard (e.g. due to faulty
montage)
- That the surrounding environment should clear from any hazards, and if there is some potential left,
accordant counteractions must be taken.
Regular inspection / maintenance
Every three months or after 12,500 measurements
(whichever occurs first)
- Control level of abrasion on attaching parts.
- Control all dimensions.
- Check on every possible deformation and
damages.
- Assure an accordant operation of all parts.
Every 12 months or after 50,000 measurements
(whichever occurs first)
- Check all parts that carry the load e.g. on hairline
cracks etc. The maintenance should be
performed by specialised personnel.
Avery 5 years or after 250,000 measurements
(whichever occurs first)
- All parts that carry the load must be replaced.
Every 10 years or after 500,000 measurements
(whichever occurs first)
- Life time of measuring device is fully consumed.
The entire measuring device must be replaced.
Only the owner or operator takes responsibility for material damage and physical injuries resulting from
improper application or violation of the guidelines. The manufacturer does not assume any liability. The
safety measures are only an extract from effective standards and guidelines, containing several notes
and advices. Those do not substitute these guidelines and standards, rather than facilitating as a courtesy
for a safe operation of the device. Please familiarize yourself with the effective standards and guidelines
in your country prior to the operation.