Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-CMM 8

Page 1: ...Analyser User Manual User manuals in various languages français italiano español português nederlands türk polski русский 中文 can be found by using our product search on www pce instruments com Last change 2 November 2020 v1 0 English ...

Page 2: ... description 2 2 1 Technical specifications 2 2 2 Display touch screen 3 2 3 Dimensions 3 3 Operating instructions 4 3 1 On off 4 3 2 Settings 4 3 3 Measurement graph data history 6 3 4 Alarms 6 3 5 CO2 traffic light function 7 4 Warranty 7 5 Disposal 7 ...

Page 3: ...ns The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case fo...

Page 4: ...ment range Accuracy Resolution 10 50 C 14 122 F 1 C 0 1 C Measured variable air humidity Measurement range Accuracy Resolution 20 95 RH 5 RH 1 RH General technical specifications Display 3 5 touch LCD Alarm display Traffic light function through colour change Alarm tone Power supply 5 V mini USB Standby power 0 5 W Environmental conditions 1 85 C 14 122 F 20 85 RH Protection class IP21 Dimensions ...

Page 5: ...time 2 Set lower or upper alarm 3 CO2 reading 4 Increase or decrease alarm value 5 Lock screen 6 Unit change C F 7 Air humidity reading in RH 8 Show progress diagramme 9 Temperature reading 10 Settings 11 Alarm message 12 On off 13 Mute alarm 2 3 Dimensions ...

Page 6: ...itch between C and F 3 2 4 Setting the display brightness Touch the menu item Backlight to adjust the display brightness using the arrow keys at the bottom right of the display If you touch the item Ambient Light Dimming the display brightness is adjusted depending on the ambient light at the time of saving 3 2 5 Standby screen Touch the menu item Standby Screen to set the time period when the dis...

Page 7: ...fset Touch the menu item Humidity Sensor to set an offset for the humidity value reading 3 2 10 Selecting the time zone Touch this menu item to set the time difference from GMT Press the key to enable synchronisation of the power on off time with the internet time To do this the meter must be successfully connected to the internet 3 2 11 Daylight saving time Touch the menu item to set the daylight...

Page 8: ...able The CO2 meter is recognised as a mass storage device In the file DATALOG TXT you can view the previously saved measurement data 3 4 Alarms Touch the number in the top right corner to set the alarm values for High and Low The CO2 meter uses these values to change the colour of the digits for the measured value and an alarm tone can be heard if selected 3 4 1 Set upper alarm High As soon as hig...

Page 9: ...isposal For the disposal of batteries in the EU the 2006 66 EC directive of the European Parliament applies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re use them or give them to a recycling company which ...

Page 10: ...e İstanbul United Kingdom SO31 4RF Italia Türkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk info pce italia it info pce cihazlari com tr www pce instruments com english www pce instruments com italiano www pce instruments com turkish The Netherlands China Hong Kong PCE Brookhuis B V PCE...

Reviews: