©  PCE Instruments 

 

2.2 

Display  

 

 

 

Audio alarm indicator 

 

Mode indicator 

 

Calibration indicator 

 

Automatic power-off 

 

Battery status 

 

Cancel calibration 

 

Measured CO

2

 value 

 

Emoticon CO

2

 value 

 

Air humidity 

 

Date / time 

 

Temperature 

 

Freeze displayed measured value  

 

 

 

 

2.3 

Function keys  

 

 

2.4 

Terms / icons  

Symbol 

Measurement modality 

HOLD 

Freeze measured values 

MAX 

Maximum measured value 

MIN 

Minimum measured value 

AVG 

Average measured value 

TWA  

Time weighted average (8 hours) 

STEL 

Short-term exposure limit (15 minutes weighted average) 

 

 

Summary of Contents for PCE-CMM 10

Page 1: ...CO2 analyser User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 27...

Page 2: ...3 2 4 Terms icons 3 3 Technical specifications 4 4 Operation 5 4 1 On off 5 4 2 Temperature 5 4 3 Alarm 5 4 4 Measurement mode 5 4 5 Backlight 5 4 6 Automatic power off 5 4 7 Charging the battery 5 4...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...PCE Instruments 2 2 System description 2 1 Device Case USB socket Display Function keys...

Page 5: ...value Emoticon CO2 value Air humidity Date time Temperature Freeze displayed measured value 2 3 Function keys 2 4 Terms icons Symbol Measurement modality HOLD Freeze measured values MAX Maximum measu...

Page 6: ...1 C Accuracy 1 C may be influenced by meter s waste heat Measurement range air humidity 0 99 RH Resolution 1 RH Accuracy 5 at 25 C between 10 90 RH Sensor NDIR principle ABC Automatic baseline correct...

Page 7: ...ss and hold the key for about 3 seconds 4 4 Measurement mode Press the MODE key to switch between the different measurement modes see 2 4 Press and hold the MODE key to delete the minimum maximum and...

Page 8: ...lues you can recalibrate the unit Two options are available for calibration 5 1 Automatic calibration The PCE CMM 10 has an integrated self correcting ABC Automatic Baseline Correction algorithm for a...

Page 9: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 10: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...