Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
 
 

 

Summary of Contents for PCE-322A

Page 1: ...E 323 Sound Level Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Las...

Page 2: ...and off 6 5 1 Making a measurement 6 6 Automatic power off 9 7 Data logging PCE 322A PCE 323 only 10 7 1 Clearing the memory 10 7 2 Setting the memory interval 10 8 Replacing the battery 10 9 Bluetoo...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...1 k Data interface USB Bluetooth 4 0 PCE 323 only Bracket 3 8 connection Functions MIN MAX HOLD display when exceeding or falling below the sound level Automatic power off after approx 15 minutes of i...

Page 5: ...truments 3 4 Device description No Description 1 Microphone with windscreen 2 Connections for power supply mini USB analogue outputs calibration screw 3 Display 4 Keyboard 5 Battery compartment rear 1...

Page 6: ...ic power off and to start the Bluetooth connection PCE 323 only 3 Switching the backlight on and off 4 FAST SLOW key to switch between fast and slow time rating 5 A C key for switching between frequen...

Page 7: ...t measured value 5 Time rating Fast fast 125 ms 6 Time rating Slow slow 1 s 7 Current measured value is above the set measurement range 8 Measurement range scale 9 Date and time 10 Measured value 11 A...

Page 8: ...le If a range is exceeded or undercut this is indicated by Over or Under 5 1 3 Setting the time rating To set the time rating press the FAST SLOW key With the Fast setting the time weighting is 125 ms...

Page 9: ...y and switch on the meter As soon as TIME is flashing you can release the SETUP key The currently set date is now displayed You can then select the minute hour day month and year one after the other u...

Page 10: ...PCE Instruments 8 Setting the hour Setting the day Setting the month...

Page 11: ...and time To do this go one function further rSt Reset is displayed for resetting Now press the HOLD key and the date and time will be reset Now you can set the date and time 6 Automatic power off To...

Page 12: ...eter Press and hold the backlight key and switch the meter back on As soon as Int is displayed you can release the backlight key Use the LEVEL key to adjust the displayed value A memory interval betwe...

Page 13: ...to activate the Bluetooth function on your PCE 323 Then open the app and connect to the meter via the app Select Environment Meter as the instrument type Note The connection must not be established v...

Page 14: ...on it 3 Then click on Install to install the driver 4 Restart the PC after the driver installation has been completed 5 Once the PC has restarted you can switch on the meter and connect it to a free...

Page 15: ...P210x USB to UART Bridge COMX then to Port Settings and Advanced Port Settings 7 Now start the software installation by executing the Setup exe in the root directory and following the information on t...

Page 16: ...ation on the version of the software 10 2 2 Real time measurement Start Time Time from the start of the measurement MIN Lowest volume of the measurement series with point in time MAX Highest volume of...

Page 17: ...and B Minimum determined value between A and B Cursor B Value cursor B Average Between A and B Measured average value between A and B Quantity Between A and B Measured values between A and B You can...

Page 18: ...measurement Stop Stop real time measurement Clear Data Clear data Setup Setting the sampling rate and maximum measured values Read out the internal data logger of the meter Manual Select communication...

Page 19: ...C Output voltage 10 mV dB Resistor 1 k 13 Calibration To perform a calibration connect the meter to a class 2 or better sound calibrator Set the meter as follows Frequency rating A Time rating Almost...

Page 20: ...ies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 21: ...Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: