Error indicators:
Differential current faults
are indicated by the signal unit
flashing RED
. In this case, the PRCD-S+ from PCE gives a visual
warning and switches off immediately. The PE conductor circuit
remains closed until the fault is cancelled!
Measuring errors
caused, for example, by the wearing a glove
when switching on are indicated by the signal unit
flashing RED
.
In this case, the PRCD-S+ from PCE
gives a visual warning and
does not switch on. After acknowledging the fault, repeat the
starting procedure without a glove or after changing your location.
If, when switching on, the signal unit
illuminates RED or
remains neutral
within approx. 2 sec., there is a
fault
. The
PRCD-S+
does not switch ON. Consult a qualified electrician
.
If there is already an
under voltage
when plugging in the
PRCD-S+ unit, the LED unit
flashes fast RED
(if there is
enough voltage available) and the unit does not switch on.
If during operation
under voltage
occurs, the unit switches off
and the LED illuminates
RED
.
If there is
over voltage
when plugging in the unit, the LEDs start
flashing
4x RED
and
1x GREEN
alternating and the unit will not
turn on.
If during operation
over voltage
occurs, the unit switches off and
the LED illuminates
RED
.
red
red
>Push
>Push
Maximum possible personal protection
is assured.