© PCE Instruments
17
Eng
li
s
h
3.6
Function keys
Key functions in programming mode
Key
Function
SEL
Increases the program steps (P00, P01 …) and the programmable
options and values
TEST
Decreases the program steps and the programmable options and
values
ENTER
Confirms entered values, ends program step
ESC
Leaves current program and moves decimal place
4
Operation of wind speed display
The wind speed sensor is coupled with the wind speed display.
The wind speed measured by the sensor is displayed when the battery is inserted into the
transmitter.
The transmitter and the receiver communicate via RF IEEE 802.15.4, at a frequency of 2.4 GHz.
The wind sensor must always be positioned vertically!
4.1
Settings
4.1.1
Alarm
The alarm is triggered when the wind speed exceeds the set value. A delay time can be set via the
function keys. This is to prevent unnecessary alarms from being triggered, for example, by wind
gusts.
When the wind speed is below the set value, no alarm will be triggered.
When ALARM 2 is activated, ALARM 1 will be deactivated. When ALARM 2 is triggered, the reading
will flash to additionally warn of strong wind gusts.
4.1.2
Standard user setting
You can save your settings as “standard user setting“ and use them again when required, see 5
, P00 - (4).
If no configuration has been saved, the same operation will restore the factory default settings.
4.1.3
Indication of minimum and maximum wind readings
The PCE
–WSAC 50W automatically records the mimnimum and maximum wind speed. Press the
ENTER key in normal measuring mode to view the lowest wind speed measured after powering on
the meter. Press the ENTER key again to view the highest measured wind speed.
The meter returns to normal measuring mode when no key has been pressed for 3 seconds.
To reset the minimum and maximum values, press and hold the ESC key for 3 seconds.
Note
: Both values will be deleted when the power supply is interrupted.