background image

 

12 

 

PCE Instruments contact information

 

 

Germany

 

 

 

PCE Deutschland GmbH

   

Im Langel 4

   

D-59872 Meschede

 

 

 

Deutschland

  

 

Tel.: +49 (0) 2903 976 99 0

 

 

 

 

Fax: +49 (0) 2903 976 99 29

 

 

 

[email protected]

 

 

 

www.pce-instruments.com/deutsch

   

France

 

PCE Instruments France EURL

   

23, rue de Strasbourg

 

 

67250 Soultz-Sous-Forets

 

France 

 

Téléphone: +33 (0) 972 3537 17

 

Numéro de fax: +33 (0) 972 3537 18

 

[email protected]

 

www.pce-instruments.com/french

 

Spain

 

PCE Ibérica S.L.

 

Calle Mayor, 53

 

02500 Tobarra (Albacete)

 

España

 

Tel. : +34 967 543 548

 

Fax: +34 967 543 542

 

[email protected]

 

www.pce-instruments.com/espanol

 

 

Germany

 

 

 

PCE Produktions- und 

 

 

 

Entwicklungsgesellschaft mbH

   

 

Im Langel 26

  

 

D-59872 Meschede

 

 

 

 

Deutschland

  

 

Tel.: +49 (0) 2903 976 99 471

 

 

 

 

Fax: +49 (0) 2903 976 99 9971

   

 

[email protected]

 

 

 

www.pce-instruments.com/deutsch

   

 

United Kingdom

 

PCE Instruments UK Ltd

 

Unit 11 Southpoint Business Park

 

Ensign Way, Southampton

 

 

Hampshire

 

United Kingdom, SO31 4RF

 

Tel: +44 (0) 2380 98703 0

 

Fax: +44 (0) 2380 98703 9

 

[email protected]

 

www.pce-instruments.com/english

 

 

Italy

 

PCE Italia s.r.l.

 

Via Pesciatina 878 / B-Interno 6

 

55010 Loc. Gragnano

 

Capannori (Lucca)

 

Italia

 

Telefono: +39 0583 975 114

 

Fax: +39 0583 974 824 

 

[email protected]

 

www.pce-instruments.com/italiano

 

 

The Netherlands

   

 

PCE Brookhuis B.V.

   

 

Institutenweg 15

   

 

7521 PH Enschede

   

 

Nederland

   

 

Telefoon: +31 (0)53 737 01 92

   

 

[email protected]

 

 

 

www.pce-instruments.com/dutch

 

 

China

 

PCE (Beijing) Technology Co., Limited

 

1519 Room, 6 Building

 

Zhong Ang Times Plaza

 

No. 9 Mentougou Road, Tou Gou District

 

102300 Beijing, China

 

Tel: +86 (10) 8893 9660

 

[email protected]

 

www.pce-instruments.cn

 

 

Hong Kong

 

PCE Instruments HK Ltd.

 

Unit J, 21/F., COS Centre

 

56 Tsun Yip Street

 

Kwun Tong

 

Kowloon, Hong Kong

 

Tel: +852-301-84912

 

[email protected]

 

www.pce-instruments.cn

 

 

United States of America

  

PCE Americas Inc.

   

 

711 Commerce Way suite 8

 

 

 

Jupiter / Palm Beach

 

 

 

33458 FL 

   

 

USA

   

 

 

Tel: +1 (561) 320-9162

 

 

 

Fax: +1 (561) 320-9176

   

[email protected]

   

 

www.pce-instruments.com/us

 

 

Turkey

 

 

PCE Teknik Cihazları Ltd.Şti.

 

Halkalı Merkez Mah.

 

Pehlivan Sok. No.6/C

 

34303 Küçükçekmece - İstanbul

 

Türkiye

 

Tel: 0212 471 11 47

 

Faks: 0212 705 53 93

 

 

[email protected]

 

www.pce-instruments.com/turkish

 

 

 
 

 

 

Summary of Contents for PCE-PH 28L

Page 1: ...PCE PH 28L Pocket pH Meter Instruction Manual ...

Page 2: ... the electrode into the meter Twist the electrode collar clockwise until it is tight Display PCE PH 28L pocket pH meter is equipped with an easy to read LCD display that used to show the measured values and mode icons The following table describes the function of each icon INDEX ICON DESCRIPTION MEAS Indicates the meter is in the measurement mode CAL Indicates the meter is in the calibration mode ...

Page 3: ...eter ON OFF Locks the measured value press the key again to resume measuring Exits the calibration or setting and returns to the measurement mode CAL Press the key to start the calibration Press and hold the key to enter the setup menu In the setting mode press the key to select the default option ENTER Confirms the calibration or selected option ...

Page 4: ...r 250ml to scale line mix the solution until the reagent is completely dissolved Preparation of pH4 01 and 10 01 standard buffer solutions are the same as above Prepared standard buffer solutions should be stored in hermetically sealed glass containers Switching the Meter On and Off Press the Meas key to switch on the meter the display shows measured value Press and hold the Meas key for 5 seconds...

Page 5: ...8 minutes Enable Disable Disable Reset the meter to factory default settings Enable Disable Disable Setting the default option 1 Press and hold the Cal key for 3 seconds to enter the setup menu the meter shows a menu item and default option 2 If necessary press the Cal key again to select the desired option 3 Press the Enter key to confirm the meter moves to the next menu item 4 Repeat the steps a...

Page 6: ...bration is recommended DO NOT reuse the pH buffer solution after calibration contaminants in solution will affect the calibration and eventually the accuracy of the measurement Single point calibration 1 1 Make sure that you have selected 1 point calibration in the setup menu 1 2 Rinse the electrode with distilled water Press the Cal key the meter shows pH7 00 CAL1 or pH6 86 CAL1 1 3 Place the ele...

Page 7: ...uffer solution Stir the electrode gently 2 4 Press the Enter key the meter automatically recognizes the current calibration solution and begins the calibration 2 5 Wait for the reading to stabilize the display automatically shows the electrode slope e g 99 and END Second point calibration is completed 3 points calibration 3 1 Make sure that you have selected 3 points calibration in the setup menu ...

Page 8: ...e slope and pH10 01 CAL3 or pH9 18 CAL3 3 6 Rinse the electrode with distilled water Place the electrode into the pH10 01 or pH9 18 buffer solution Stir the electrode gently 3 7 Press the Enter key the meter begins the calibration 3 8 Wait for the reading to stabilize the display automatically shows the electrode slope and END Calibration is completed If you want to exit the calibration press the ...

Page 9: ...d hold the Cal key for 3 seconds to enter the setup menu 2 Press the Enter key until the meter shows C CAL or F CAL 3 Press the Cal key to enter the temperature calibration mode 4 Press the Cal key again to modify the temperature value 5 Press the Enter key to confirm the meter shows the next menu item 6 Press the Meas key to return to the measurement mode Calibration is completed ...

Page 10: ...ume measuring Electrode Care and Maintenance For best results please always keep the glass sensitive membrane wet Ensure that the electrode is thoroughly washed with distilled or deionized water after use If you do not use the meter for long periods store the electrode into the 3M KCL solution Electrode Replacement When the meter fails to calibrate or gives fluctuating readings for calibration sta...

Page 11: ... to select an applicable sensor ELECTRODE ORDER CODE DESCRIPTION General purpose pH electrode suitable for measuring the non viscous non corrosive liquids Flat surface pH electrode suitable for measuring the semisolid substances e g cheese meats paper etc Specifications pH Model PHscan30L Range 1 00 15 00pH Accuracy 0 01pH Resolution 0 01pH Calibration Points 1 to 3 points pH Buffer Options USA pH...

Page 12: ...ts batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re use them or give them to a recycling company which disposes of the devices in line with law For countries outside the EU batteries and devices should be disposed of in accordance with your...

Page 13: ...l needs com www pce instruments com english Italy PCE Italia s r l Via Pesciatina 878 B Interno 6 55010 Loc Gragnano Capannori Lucca Italia Telefono 39 0583 975 114 Fax 39 0583 974 824 info pce italia it www pce instruments com italiano The Netherlands PCE Brookhuis B V Institutenweg 15 7521 PH Enschede Nederland Telefoon 31 0 53 737 01 92 info pcebenelux nl www pce instruments com dutch China PCE...

Reviews: