The STATIC test should always be carried out before a gas-detection operation. If there are strong charges, a 
gas-detection operation should not be carried out, since the static charge is renewed when a person moves 
around and new sparks may be created during the gas-detection operation. 

Alarm 

If the detector produces an alarm (beep tone and red LED shines), gas is leaking from the object. Depending on 
the amount of leaking gas, you should immediately open all windows and doors, and avoid both open fire and 
the creation of sparks. Do not operate electrical switches. Leave the room. If possible, turn off the gas supply. 
 

You should immediately inform an expert about leaking gas systems. Do not try to deal with the fault yourself! 

 

8.  Inspecting the gas-leak detector 

Hold a gas lighter close to the gas sensor (1). Let gas leak out of the lighter without the flame of the lighter 
burning. The gas-leak detector should now produce a beep tone and the red display LED (2) should shine. 
If this is not the case, either the batteries are empty or the gas-leak detector is defective. 

9. False alarm 

Due to the high sensitivity of the detector, a false alarm due to other gaseous materials such as aerosols (hair 
sprays, propellant gas, cigarette smoke etc.) cannot be excluded. 

10. Maintenance and disposal 

Maintenance 

Check the gas-leak detector regularly for technical reliability. It can be assumed that safe operation has become 
impossible, if: 

z

 

the device shows visible damage 

z

 

the device was stored under unfavourable conditions for a long period of time 

z

 

it was exposed to extraordinary stress caused by transport 

z

 

the test function described above no longer runs correctly. 

 
Use a sort, dry cloth or brush to clean the outside of the device. Never use aggressive cleaning agents or 
chemicals, since they may damage the housing or impair the function of the device. 
 
Avoid touching the gas sensor (1) or cleaning it in any way. Apart from the battery chamber, do not try to open 
the housing. 

Disposal 

Dispose of the unserviceable device according to legal and statutory regulations. 

Technical data 

Operating voltage……:3VDC (2x micro batteries, alkaline) 
Power consumption…:approx.200mA Types of gas to which the device responds: Propane and natural gas (for 

the most part a mixture of hydrocarbons, natural gas, normally consisting of 80-95% 
various other gases, such as carbon dioxide, carbon monoxide and helium) 

Sensitivity: 

    Min 

 

 

  Max  

Propane 

            500ppm 

             6500ppm 

Natural gas 

          1000ppm                          6500ppm 

Operating life………….depending on type of battery used approx. 4 hours. 
Weight…………………46g 
Dimensions……………180mm (L) x 21mm (diameter) 

11. Surrounding  conditions 

Working temperature :10ºC to 50ºC 
Relative humidity….. :<95%(not condensing) 
Storage temperature.:5 ºC to 55 ºC 

 

Summary of Contents for PCE-GA 3

Page 1: ...ale Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial need...

Page 2: ...R INSTRUCTIONS 3 4 CONTROL ELEMENTS 4 5 INSERTING THE BATTERIES AND BATTERY EXCHANGE 4 6 COMMISSIONING AND OPERATION 5 7 STATIC DISCHARGE 5 ALARM 6 8 INSPECTING THE GAS LEAK DETECTOR 6 9 FALSE ALARM 6...

Page 3: ...in case of complex gas systems such as heaters or ovens you should not carry out the measurement yourself but contact an expert The device is not suitable for those types of measurements Do not put yo...

Page 4: ...ers an alarm due to the detection of gas 3 POWER display LED This LED shines when the device is switched on and the batteries still have sufficient capacity The LED does not shine when the batteries a...

Page 5: ...ce no beep tone or the red LED may not shine etc This is why after switching it off you should wait 60 seconds before switching the device back on z When the beep tone has stopped and the green displa...

Page 6: ...ke etc cannot be excluded 10 Maintenance and disposal Maintenance Check the gas leak detector regularly for technical reliability It can be assumed that safe operation has become impossible if z the d...

Page 7: ...irection will find a vision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potential...

Reviews: