1.0 INTRODUCTION 

 
General  purpose  canister  load  cells  manufactured  by  PCB 
Load & Torque are suitable for a wide range of general force 
measurement  applications,  including  weighing,  dynamometer 
use,  and  static  material  test  machines.    These  load  cells 
operate in tension and compression.  Standard 1/4”-28 female 
threads facilitate ease of installation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The  following  document  explains  the  characteristics  and 
installation of the canister load cells. 

 
 

2.0 SAFETY PRECAUTIONS 

 
Failure  of  the  load  cell  structure  may  cause  personal  injury 
and equipment damage.   
 
The load cell can withstand loads of at least 150% of the full-
scale  capacity  before  any  damage  occurs  to  the  sensing 
element.    Be  sure  that  the  load  cell  and  any  fixturing  used  is 
properly  designed,  fabricated,  and  securely  installed  prior  to 
use. 
 
 

3.0 OVERVIEW 

 
Canister  load  cells  come  in  a  variety  of  capacities  to  handle 
loads ranging from 25 lbf to 300 lbf.   
 
 
 
 
 
 
 
 
 
 
 
 

3.1 Dimensions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.2 Optional Components 

 
 
 
 
 

 

4.0 MECHANICAL INSTALLATION 

 
Loads applied to canister load cells must be even and centered.  
Compensation  linkages  (e.g.  rod  end  bearing,  alignment 
couplers)  are  recommended  to  help  minimize  load 
misalignment.  When installing  fixtures, be sure to thread the 
fixture to the load cell, and not the load cell to the fixture.  If 
alignment  fixtures  are  not  used,  ensure  loading  surfaces  are 
flat and parallel, with loads applied in-line with the sensor. 
 

Figure 2

 

- Dimensions 

Table 2

 

- Dimension Values 

Table 1 -

 

Full-Scale Capacities 

Figure 1 –

 

Canister Load Cell Loading 

Full-Scale Capacities 

Model 

(lbf) 

(N) 

1102-05A 

25 

110 

1102-01A 

50 

222 

1102-02A 

100 

445 

1102-03A 

200 

900 

1102-04A 

300 

1334 

M1102-05A 

28 

125 

M1102-01A 

56 

250 

M1102-02A 

112 

500 

M1102-03A 

225 

1000 

M1102-04A 

337 

1500 

 

Dimensions 

(see Figure 2)

 

Series Number 

1102 

M1102 

(in) 

(mm) 

(in) 

(mm) 

2.75 

69.9 

2.75 

69.9 

0.44 

11.2 

0.44 

11.2 

1.75 

44.5 

1.75 

44.5 

1.50 

38.1 

1.50 

38.1 

0.09 

2.3 

0.09 

2.3 

0.06 

1.5 

0.06 

1.5 

3.17 

80.5 

3.17 

80.5 

¼”-28 Tapped 

M6x1.0 Tapped 

¼”-28 Tapped 

M6x1.0 Tapped 

 

 

 

 

 

Tensile Load 

Tensile Load 

 

Compression Load 

Compression Load 

Item Number 

Description 

181-012A 

PT06A-10-6S (SR), Mating Connector 

8311-01-10A 

Cable – Non-Coax, PT65 to Pigtail, 10 feet 

 

Table 3

 

- Optional Components 

Summary of Contents for 1102-05A

Page 1: ...stallation and Operating Manual For assistance with the operation of this product contact PCB Load Torque Inc Toll free 866 684 7107 24 hour SensorLine 716 684 0001 Fax 248 888 8266 E mail LTInfo pcbl...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...ng Considerations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 4 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibrat...

Page 7: ...ts 4 0 MECHANICAL INSTALLATION Loads applied to canister load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to help minimize load misalig...

Page 8: ...nstrument or control system is grounded through its power cord Ground loops and measuring system wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the pow...

Page 9: ...eg of the bridge to apply the shunt resistor to for both tension and compression load simulation Typically tension is simulated by inserting the shunt resistor between the P and S connector leads Comp...

Page 10: ...signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 10 0 CALIBRATION REPAIR SERVICES PCB Load Torque offers calibration an...

Page 11: ...x 38 1 mm 7 Weight 0 67 lb 304 g Mounting Thread 1 4 28 Female No Metric Equivalent Housing Material Painted Aluminum Painted Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale...

Page 12: ...FULL 1102 SERIES PT CONN CANNISTER LOAD CELL PTE 9 14 11 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 51277 PCB Load Torque Inc claims proprietary rights in the information disclosed hereon Neither i...

Reviews: