background image

Model RHM240A02

Uniaxial ICP® Strain Sensor

Installation and Operating Manual

For assistance with the operation of this product,

contact PCB Piezotronics, Inc.

Toll-free: 800-828-8840

24-hour SensorLine: 716-684-0001

Fax: 716-684-0987

E-mail: [email protected]

Web: www.pcb.com

Summary of Contents for RHM240A02

Page 1: ...ain Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...model number s purchased The following pages give a brief description of the sensor series recommended mounting procedures operation and recommended calibration In addition to standard products PCB h...

Page 7: ...ould remain on the connector to prevent contamination or damage For installation in dirty humid or rugged environments it is suggested that the connection be shielded against dust or moisture with shr...

Page 8: ...ning to all ICP instrumentation Most of the signal conditioners manufactured by PCB have an adjustable current feature allowing a choice of input currents from 2 to 20 mA In general for lowest noise b...

Page 9: ...ortant to DC couple the entire system and not just from the sensor to the signal conditioner The system time constant is determined by the shortest time constant in the system For this reason the sign...

Page 10: ...allow this output voltage to decay 5 DTC s prior to making measurements in order to prevent baseline shift where an absolute zero is needed throughout entire monitoring process 10 0 MAINTENANCE The s...

Page 11: ...ngth x Height 0 67 in x 1 81 in x 0 6 in 17 mm x 46 mm x 15 2 mm Weight 1 6 oz 45 gm 1 All specifications are at room temperature unless otherwise specified In the interest of constant product improve...

Page 12: ...17 MJK 09 27 17 22493 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent...